The laser beam can be switched off through a software command (see also the Genius™ Help On-Line). 
 
 

 

AVOID EXPOSURE 

LASER LIGHT IS EMITTED 

FROM THIS APERTURE 

CAUTION-CLASS 3B 

LASER LIGHT 

WHEN OPEN 

AVOID 

EXPOSURE TO BEAM 

 

 

AVOID EXPOSURE 

LASER RADIATION IS EMITTED FROM THIS APERTURE 

 

Laser Safety Label 

 
 

 

 

LASER LIGHT 

DO NOT STARE INTO BEAM 

CLASS 2 LASER PRODUCT

 

MAXIMUM OUTPUT RADIATION 1 mW 
EMITTED WAVELENGTH 630~680 nm 

TO EN 60825-1:2001

 

 

 

Model No. 

Amp. 

Serial No. 

DATALOGIC S.P.A.  Via Candini,  2 
40012 Calderara di Reno - Bologna - Italy 
Manufactured Volt 

This product conforms to the applicable requirements 
of 21CFR1040 at the date of manufacture. 

 

 

 

Warning and Device Class Label 

Device Identification Label 

 
 
The laser diodes used in this device are classified as Class 3B laser products according to EN 60825-1 
regulations and as Class IIIb laser products according to CDRH regulations. Any violation of the optic parts in 
particular can cause radiation up to the maximum level of the laser diode (30 mW at 630~680 nm). 
 
 

Power Supply 

This product is intended to be installed by Qualified Personnel only.

 

This scanner is intended to be supplied by either a UL Listed power supply marked 'Class 2' or 'LPS', output rated 
20 - 30 V dc, minimum 1.5 A or by a UL Listed computer with LPS outputs. 
 
DS8100A-3002 must be supplied by a Class II Power Supply Unit conforming to the EN 60950 safety regulation. 
 
 

Patents: 

 
This product is covered by one or more of the following patents. 
  
U.S. patents: Re. 36,251; 5,483,051; 5,992,740; 6,177,979 B1; 6,347,740 B1; 6,394,352 B1; 6,443,360 B1; 
6,527,184 B1; 6,629,639 B2; 6,688,524 B1; 6,742,710 B2; 7,161,685 B1; 5,028,772; 5,124,538; 5,466,921; 
5,548,107; 6,206,289 B1; 6,669,091 B2; 7,000,838 B2. 
 
European patents: 652,530 B1; 789,315 B1; 851,376 B1; 926,615 B1; 959,426 B9; 1,363,228 B1. 
 
Japanese patents: 3,793,585; 4,033,958. 
 
Additional patents pending. 
 

Summary of Contents for DS8100A-3002

Page 1: ...DS8100A 3002 QUICK REFERENCE GUIDE ...

Page 2: ...3 Power On LED Green 2 TX Data LED Green 5 Network LED Red 6 Encoder LED Yellow 4 LCD Display 7 Figure C Lonworks 17 pin Male Connector 1 Lonworks 17 pin Female Connector 2 NOTE For further details on product installation see the complete Reference Manual available on the configuration CD ROM included with this product 1 1 2 7 1 2 3 4 5 6 ...

Page 3: ... keys LED Indicators Power ON green Phase ON yellow Encoder yellow TX Data green Network red SOFTWARE FEATURES Operating Modes PackTrack Config Mode Genius utility program Parameter Storage Non volatile internal FLASH Readable Codes Interleaved 2 5 Code 39 standard Codabar Code 128 EAN 128 Code 93 standard full ASCII EAN UPC Code Selection Up to 10 codes during one reading phase ENVIRONMENTAL FEAT...

Page 4: ...alogic WebSentinel 020 Supervisor up to 20 arrays 93A101016 Datalogic WebSentinel 032 Supervisor up to 32 arrays 93A101017 Datalogic WebSentinel 064 Supervisor up to 64 arrays 93A101018 Datalogic WebSentinel 128 Supervisor up to 128 arrays 93A101019 Datalogic WebSentinel 256 Supervisor up to 256 arrays 93A101020 Electrical Connections Two 17 pin connectors provide access to the scanner s local Lon...

Page 5: ...C6003 CAB SC6013 Power Net VAC INPUT CAB SC6103 Cable PWO LONWORKS ENCODER PS PS Aux CAB 850x CAB 850x CAB 850x CAB 850x CAB 850x up to 3 scanners per branch BTK8500 Bus Return DX8200A 3002 DS8100A 3002 CAB 850x up to 4 scanners per branch BTK8500 Bus Return DX8200A 3002 DX8200A 3002 DS8100A 3002 DS8100A 3002 DS8100A 3002 CAB 850x ...

Page 6: ...Aux CAB 850x CAB 850x BTK8500 CAB 850x CAB 850x CAB 850x Extended I O ETHERNET SC6000 CAB SC6003 CAB SC6013 Power Net VAC INPUT PWO CAB PWO 03 Redundancy CAB 850x CAB 850x CAB 850x BTK8500 DX8200A 3002 ENCODER PS PS Aux LONWORKS Working Controller Protecting Controller to Host to Host DX8200A 3002 DX8200A 3002 DX8200A 3002 DS8100A 3002 DS8100A 3002 DS8100A 3002 DS8100A 3002 ...

Page 7: ...DS8100A 3002 QUICK GUIDE 7 Example of Redundant System ...

Page 8: ... 45 1 77 17 5 0 68 8 5 N 4 0 33 DS8100A 3002 Overall Dimensions ST 163 Mounting Bracket Overall Dimensions WARNING When installing several scanners take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners This condition could occur more frequently for side mounted applications If these precau...

Page 9: ... 20 16 24 Safety Precautions Figure A Laser Safety Label 1 Warning and Device Class Label 2 Identification Label 3 The scanner is classified as a Class 2 laser product according to EN60825 1 regulations and as a Class II laser product according to CDRH regulations Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light There...

Page 10: ...lations and as Class IIIb laser products according to CDRH regulations Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode 30 mW at 630 680 nm Power Supply This product is intended to be installed by Qualified Personnel only This scanner is intended to be supplied by either a UL Listed power supply marked Class 2 or LPS output rated 20 30 V...

Page 11: ... la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto Questa dichiarazione è basata sulla confor...

Reviews: