DS6500
42
2
Multi P.S. (This system configuration will be available soon).
In this layout, up to 7 DS6500 slave readers have their own P.S. and therefore multiple
reading phases, while the P.S. activating the master reader is managed by the C-BOX 100.
The master sends all the individual messages collected from the multidrop line as well as its
own to the C-BOX 100 which passes them to the Local Host.
The following image shows a system consisting of four readers, where the fourth one must
be connected to a dedicated power supply by means of a C-BOX 100, since a single
C-BOX 100 can supply groups consisting of maximum 3 readers. This means that the cable
(CAB611X) connecting two different groups, in this case the cable connecting Slave 2and
Slave 3, does not propagate power.
Figure 68 – Multi P.S. with more than 3 Readers
2.7.6 Fieldbus
Network
The Fieldbus (Ethernet, Profibus and DeviceNet) model offers connectivity without any
converter or adapter needed.
The DS6500 master Fieldbus communicates with a remote host (for ex. remote PC
connected via Internet) by means of a cable connected to the Fieldbus (Ethernet, Profibus or
DeviceNet) connector provided.
The local Lonworks 9-pin female connector connects the Fieldbus master reader to the first
slave reader of the system, while the 26 D-sub male connector may be connected to the
C-BOX 100 to supply the reader.
The slave readers (DS6500 master/slave models) are connected together through the local
Lonworks connectors. Only the 9-pin female connector of the last slave reader must be
terminated by the BTK-6000 terminator. No terminator must be inserted in the Fieldbus
master reader, since it is internally integrated.
P.S.
P.S.
P.S.
P.S.
Slave 1
Master
Slave 2
Slave 3
CAB610X
CAB611X
PWR-120
C-BOX 100
CAB610X
C-BOX 100
CAB600X
Local Host