![Datalogic DS2100N Reference Manual Download Page 32](http://html.mh-extra.com/html/datalogic/ds2100n/ds2100n_reference-manual_511867032.webp)
DS2100N REFERENCE MANUAL
22
2
Reset Scanner to Factory Default
If it ever becomes necessary to reset the scanner to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the scanner. At the end of the procedure (about 5-6 seconds), the Configuration and
Environmental parameters are reset, all LEDs blink simultaneously 3 times and the message
"Default Set" is shown on the display.
2.4 MODEL DESCRIPTION
The DS2100N scanner is available in versions that differ in regard to the following
parameters:
Resolution
Performance
Linear or raster reading
DS2100N - X X X X
Optical Resolution
1 = Standard resolution
2 = High resolution
Communication Interface
2= RS232/RS4 RS232 aux
+ RS485 ID-NET™
Optic Version
0 = Linear
1 = Raster R1
Performance
0 = Standard
4 = High Performance
The following tables display each version’s reading performance.
Version Max
Code
Resolution Speed
mm
(mils)
scans/s
12X0
0.20 (8)
500 to 800
12X4
0.15 (6)
800 to 1000
22X0
0.15 (6)
500 to 800
22X4
0.12 (5)
800 to 1000
Version Reading
Distance
12X0
40 mm (1.6 in) - 300 mm (11.8 in) on 0.50mm (20 mils) codes
12X4
50 mm (1.8 in) - 310 mm (11.8 in) on 0.50 mm (20 mils) codes
22X0
30 mm (1.2 in) - 90 mm (3.5 in) on 0.30 mm (12 mils) codes
2XX4
45 mm (1.8) – 100 mm (3.9 in) on 0.20 mm (8 mils) codes
See reading diagrams in par. 7.4 for further details.