![Datalogic DS1100 SH2347 Programming Manual Download Page 48](http://html.mh-extra.com/html/datalogic/ds1100-sh2347/ds1100-sh2347_programming-manual_511859048.webp)
40
User’s / Programming Guide
Transmission of the last character in a UPC symbol (the check digit) is
disabled by scanning Option QF, or is enabled by scanning Option
QG.
QF
Disable Transmission of Check
Digit
QG
Enable Transmission of Check
Digit *#
Scanning QJ causes UPC-A labels to be transmitted as EAN-13
labels. Scanning QK disables this feature.
QJ
Enable UPC to EAN Translation
QK
Disable UPC to EAN Translation
*#@
QN
Disable second beep on
Supplement decoded *
QO
Enable second beep on
Supplement decoded
QP
Set supplement retry count (16 by
default) range = 1-32
QR
Disable transmissionof UPC-E
check digit
Summary of Contents for DS1100 SH2347
Page 4: ...NOTES ...
Page 8: ...iv User s Programming Guide NOTES ...
Page 61: ...06656 53 Digit Selection 5 0 6 1 7 2 8 3 9 4 ...
Page 69: ...06656 61 XE Active Polarity High XF Active Polarity Low ...
Page 73: ...06656 65 300 ms 50 MS 350 MS 100 MS 400 MS 150 MS 450 MS 200 MS 500 MS 250 MS ...
Page 85: ...06656 77 NOTES ...