DRAGON™ D131/M131
168
5.15 DEFAULT PARAMETERS FOR POS TERMINALS
The default values of the RS232 and Data Format parameters for POS terminals are
listed in the following table:
NIXDORF Mode A
FUJITSU
ICL Mode
RS232 Group
Baud Rate
9600
9600
9600
Parity Odd
None
Even
Data Bits
8
8
8
Stop Bits
1
1
1
Handshaking
Hardware (RTS/CTS)
None
RTS always ON
ACK/NACK Protocol
Disabled Disabled Disabled
FIFO Disabled
Enabled
Enabled
Inter-Character Delay
Disabled Disabled Disabled
RX Timeout
9.9 sec
2 sec
9.9 sec
Serial Trigger Lock
Disabled Disabled Disabled
Data Format Group
Code Identifier
Custom
Custom
Custom
Header
No Header
No Header
No Header
Terminator CR
CR
CR
Field Adjustment
Disabled Disabled Disabled
Code Length TX
Not Transmitted
Not Transmitted
Not Transmitted
Character Replacement
Disabled Disabled Disabled
Address Stamping
Disabled Disabled Disabled
Address Delimiter
Disabled Disabled Disabled
Time Stamping
Disabled Disabled Disabled
Time Delimiter
Disabled Disabled Disabled
The table below lists all the Code Identifiers available for the POS terminals:
CODE
NIXDORF Mode A
FUJITSU
ICL Mode
UPC-A A0
A
A
UPC-E C0
E
E
EAN-8 B
FF
FF
EAN-13 A
F
F
Code 39
M
None
C [code length]
Codabar
N
None
N [code length]
Code 128
K
None
L [code length]
Interleaved 2 of 5
I
None
I [code length]
Code 93
L
None
None
Industrial 2 of 5
H
None
H [code length]
UCC/EAN 128
P
None
L [code length]
MSI O
None
None
RSS E
None
None
Other None
None
None
Summary of Contents for Dragon D131
Page 1: ...Dragon D131 M131 Reference Manual ...
Page 10: ...x OM 30X0 C 3000 CRADLES Figure C OM 3000 Figure D C 3000 LEDs LEDs ...
Page 15: ...INSTALLATION 5 2 3 RS232 CONNECTION 2 4 USB if required ...
Page 16: ...DRAGON DX31 MX31 6 2 5 IBM USB POS if required ...
Page 17: ...INSTALLATION 7 2 6 WEDGE CONNECTION 2 7 PEN EMULATION CONNECTION ...