background image

DIAMOND™ D531 

 

USING DIAMOND™ 

 
The Datalogic Diamond™ D531 is an omni-directional scanner, which 
generates a scan pattern of 16 lines, thus ensuring high performance scanning. 
 
Barcodes are read simply on presentation to the scanner window. 
 
The Diamond™ scanner can be used 

handsfree

 as well as 

hand-held

, e.g.: 

 
a)  Handsfree scanning by presenting the item to the scanner using a 

sweeping curved motion towards the scanner window. 

 

 

 

 
 
b)  You can also use it as a hand-held device by presenting the scanner to the 

item using a sweeping curved motion towards the item. 

 

 

 

 
 

SLEEP STATE 

 
After a default stand-by timeout the scanner enters a "Sleep" state for minimum 
power consumption in which the scanner Laser is OFF and the motor is not 
rotating. 
 
It is possible to exit this state by simply pressing the trigger. 

 

 

Summary of Contents for DIAMOND D531

Page 1: ...DIAMOND D531 Scanners Quick Reference ...

Page 2: ......

Page 3: ...Diamond D531 Scanners QUICK REFERENCE ...

Page 4: ...s without prior notification Datalogic shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the use of this material Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Datalogic S p A 2005 2006 820001591 Rev B ...

Page 5: ...ecting the Cable 5 Interface Selection 5 USB Interface Configuration 6 USB Interface Selection 9 USB Keyboard Nationality 10 RS232 Reader Configuration 11 Wedge Interface Selection 12 Wedge Keyboard Nationality 15 Default Values 16 Operating Test 18 Technical Features 19 Reading Diagram 20 Scanner Data Entry 21 Warranty 21 iii ...

Page 6: ...Patents 22 Services and Support 22 Compliance 23 iv ...

Page 7: ...ises à jour de drivers et documentation de ce produit sont disponibles sur Internet Ce manuel est aussi disponible en version française Cliquez sur www datalogic com D Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt Die deutschsprachige Version dieses Handbuches ist auch verfügbar Adresse www datalogic com E En Internet están disponibles las versio...

Page 8: ...vi ...

Page 9: ...ld e g a Handsfree scanning by presenting the item to the scanner using a sweeping curved motion towards the scanner window b You can also use it as a hand held device by presenting the scanner to the item using a sweeping curved motion towards the item SLEEP STATE After a default stand by timeout the scanner enters a Sleep state for minimum power consumption in which the scanner Laser is OFF and ...

Page 10: ...ll appear but barcodes cannot be decoded 2 Position the presentation scanner over the code to read and press the trigger within 5 seconds to decode the code When using the scanner for data entry a programmable timeout is provided to assure that Diamond will return to raster mode if barcode reading is not successful in single line Single Line Decoding Duration Also a programmable timeout is availab...

Page 11: ...aution you prevent any electrical damage You are advised to install the scanner in a place with good air circulation out of direct sunlight In order to install the scanner 1 Locate the optimal scanner position in relation to the counter surface 2 Pay attention to the product flow the distance to the counter edge and convenience for the operator RS232 3 ...

Page 12: ...DATALOGIC USB if required KEYBOARD WEDGE 4 ...

Page 13: ...D531 CONNECTING DISCONNECTING THE CABLE Interface Cable Connector INTERFACE SELECTION Follow the procedure to configure the interface required by your application USB Interface RS232 Interface Wedge Interface 5 ...

Page 14: ...om the dialog box the first time only If the Host supplies sufficient power to the reader the start up phase ends correctly the green LED stops blinking and the reader emits the beep OK signal If the Host does not supply sufficient power to the reader a dialog box will appear on the Host and the reader will be blocked green LED continues blinking In this case disconnect the USB cable at the Host g...

Page 15: ...ct external power supply to cable and power up Reconnect reader cable to Host and close dialog box NO YES Read test codes Scanner is READY Load drivers if required Load drivers if required Green LED blinks Green LED off BEEP OK BEEP OK Green LED off Successive start ups will automatically recognize the previously loaded drivers If external power is used verify that external power is already suppli...

Page 16: ... LED blinks Green LED off BEEP OK BEEP OK Connect Diamond to Host Disconnect scanner at Host Connect external power supply to cable and power up Reconnect reader cable to Host and close dialog box Does a dialog box appear warning that Bus power is not sufficient Green LED off 8 ...

Page 17: ...Î USB KBD APPLE Ì UA05 FÎ USB COM Ì UA02 4Î USB IBM Table Top Ì UA00 Î USB IBM Hand Held Ì UA01 Î When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site http www datalogic com 9 ...

Page 18: ...NALITY USB KBD users should select one of the following keyboard nationality codes Belge Ì FJ7 8Î Deutsch Ì FJ3 Î English Ì FJ4 Î Español Ì FJ6 3Î Français Ì FJ2 ÊÎ Italiano Ì FJ1 ÅÎ Svenskt Ì FJ5 Î USA Ì FJ0 Î Japanese Ì FJ8 Î 10 ...

Page 19: ...IGURATION Read the restore default code then read the interface selection code for your application RESTORE DEFAULT Ì oÎ RS232 INTERFACE Standard Ì CP0 Î POS TERMINALS Nixdorf Mode A Ì CM2EC0 Î Fujitsu Ì CM1 ÈÎ ICL Mode Ì CM0 ÃÎ 11 ...

Page 20: ...the restore default code then read the interface selection code for your application RESTORE DEFAULT Ì oÎ WEDGE INTERFACE IBM AT or PS 2 PCs Ì CP500 aÎ IBM XT Ì CP503 vÎ PC Notebook Ì CP505 ÈÎ IBM SURE1 Ì CP506 Î IBM Terminal 3153 Ì CP504 Î 12 ...

Page 21: ...oard Ì CP502 oÎ make break keyboard Ì CP501 hÎ KEYBOARD TYPE advanced keyboard Ì FK1 ÉÎ typewriter keyboard Ì FK0 ÄÎ ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is O...

Page 22: ...TALOGIC WEDGE INTERFACE CONTINUED WYSE TERMINALS ANSI Keyboard Ì CP509 9Î PC Keyboard Ì CP510 gÎ ASCII Keyboard Ì CP511 nÎ VT220 style Keyboard Ì CP514 ÇÎ DIGITAL TERMINALS VT2xx VT3xx VT4xx Ì CP512 uÎ 14 ...

Page 23: ...ng the following codes the one that matches your Keyboard Nationality Belge Ì FJ7 8Î Deutsch Ì FJ3 Î English Ì FJ4 Î Español Ì FJ6 3Î Français Ì FJ2 ÊÎ Italiano Ì FJ1 ÅÎ Svenskt Ì FJ5 Î USA Ì FJ0 Î The following Keyboard Nationality selection is only valid for IBM AT compatible PCs Japanese Ì FJ8 Î 15 ...

Page 24: ...ontrol disabled DATA FORMAT code identifier disabled no field adjustment code length not transmitted no header terminator CR LF character replacement disabled RS232 Nixdorf DEFAULT SETTINGS 9600 baud parity odd 8 data bits 1 stop bit handshaking hardware RTS CTS delay disabled rx timeout 9 9 sec ack nack disabled serial decode control disabled serial sleep control disabled DATA FORMAT code identif...

Page 25: ...onsecutive readings 0 3 sec beeper intensity high tone 2 beeper type monotone beeper length short single line decoding duration 5 sec timeout OFF before raster 2 sec DECODING PARAMETERS ink spread disabled overflow control enabled interdigit control enabled decoding safety one read code 39 stitching enabled code 128 stitching enabled CODE SELECTION Enabled codes EAN 8 EAN 13 UPC A UPC E without AD...

Page 26: ... Code 39 Normal 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0 1 2 3 4 5 6 7 8 4 YOUR SCANNER IS NOW READY TO READ CODES To change the defaults refer to the Presentation Scanners Software Configuration Manual or to the DL Sm rtSet Configuration program both downloadable from the website 18 ...

Page 27: ...ng diagram Max Resolution 0 10 mm 4 mils PCS Min 20 Datalogic Test Chart Scan Pattern 4 directions 16 lines Scan Rate 1200 scans seconds Environmental Features Operating Temperature 0 to 40 C 32 to 104 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 0 to 90 RH non condensing Drop Resistance IEC 68 2 32 Test ED 0 8 m ESD Protection 16 KV Protection Class IP20 Mechanical Features Weight without...

Page 28: ...DATALOGIC READING DIAGRAM Reading Zones 15 skew angle 0 2 4 6 8 10 cm 14 16 18 12 4 3 2 1 0 1 2 3 4 CODE 39 0 21 mm 8 mils CODE 39 0 10 mm 4 mils EAN13 M 1 0 33 mm 13 mils 20 ...

Page 29: ... blinking slow it blinks slower when the scanner is in Sleep mode Green Red blinking alternatively they turn on alternatively during serial configuration 1 only the Beeper Intensity command can modify these signals 2 the data entry good read tone is user configurable with all the Beeper commands in the Reading Parameter section WARRANTY Datalogic warranties this product against defects in workmans...

Page 30: ... as technical support through its website Log on to www datalogic com and click on the links indicated for further information including PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software Utilities including DL Sm rtSet a Windows based utility program which allows device configuration using a PC It provides RS232 interface configur...

Page 31: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures R...

Page 32: ...patibility and product safety Basées sur la législation des Etates membres relative à la compatibilité électromagnétique et à la sécurité des produits Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las ...