Keyboard Interface
Wedge Quiet Interval
Specifies the amount of time the scanner looks for keyboard activity before it breaks the
keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms
increments.
NOTE
This feature applies ONLY to the Keyboard Wedge interface.
1.
Determine the desired setting in milliseconds.
2.
Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
3.
Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Prog.
Mode.
4.
Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5.
Scan the appropriate two digits from the keypad in
, that represent the
duration which was determined in the steps above. You will hear a two-beep indication
after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar code to
abort and not save the entry string. You can then start again at the beginning.
6.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wedge Quiet Interval. See the table below for
examples of how to set this feature.
Table 13. Wedge Quiet Interval Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
10ms
150ms
600ms
850ms
2
Divide by 10 (and pad with
leading zeroes)
01
15
60
85
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT WEDGE QUIET INTERVAL SETTING
5
Scan Two Characters From
‘0’ and ‘1’
‘1’ and ‘5’
‘6’ and ‘0’
‘8’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Cobalto CO5300
Page 12: ...Contents x Cobalto CO5300 Scanner NOTES ...
Page 26: ...Setup 14 Cobalto CO5300 Scanner NOTES ...
Page 44: ...Enter Exit Programming Mode Enable Character 32 Cobalto CO5300 Scanner NOTES ...
Page 228: ...Enter Exit Programming Mode Plessey 216 Cobalto CO5300 Scanner NOTES ...
Page 254: ...References 242 Cobalto CO5300 Scanner NOTES ...
Page 260: ...Technical Specifications 248 Cobalto CO5300 Scanner NOTES ...
Page 274: ...Standard Defaults 262 Cobalto CO5300 Scanner NOTES ...
Page 278: ...Sample Bar Codes 266 Cobalto CO5300 Scanner NOTES ...
Page 280: ...Keypad 268 Cobalto CO5300 Scanner 5 6 7 8 9 A B C ...
Page 281: ...Product Reference Guide 269 D E F ...