
CBX800 INSTALLATION MANUAL
8
NOTE
Vdc is electrically connected to +V, just as GND is electrically connected to -V. This is useful
for supplying external trigger, inputs and outputs from the CBX800 power source, however
+V and -V signals should not be used as power supply inputs to the CBX800.
The power supply must be between 10 and 30 Vdc only.
SYSTEM WIRING
The connection and wiring procedure for CBX800 is described as follows:
1) Open the CBX800 by unscrewing the four cover screws.
2) Verify that the CBX800 power switch is off (see Figure 4).
3) Unscrew the compression connectors and pass all the system cables through them into the CBX800 housing.
4) To connect the power and input/output signals:
Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm.
Using a device such as a screwdriver, push down on the lever directly next to the clamp (see Figure 5).
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
5) Tighten the compression connector nuts so that the internal glands seal around the cables.
Figure 5 - System Cable Connections
Flexible stranded wire should be used and must meet the following specifications.
All positions:
24 - 16 AWG
0.2 - 1.5 mm²
The CBX800 spring clamp connector pinouts are indicated in the Pinout table.
Refer to the reading device Installation Manual for signal details.