TECHNICAL SUPPORT
84
AREX™ 400
MAINTENANCE
The ordinary maintenance program of the laser marker includes only simple operations.
Some operations consist in a mere “check” of the operating condition.
The maintenance activities must be done in compliance with the legal directives regard-
ing the safety rules during these operations.
The following parts/functions have to be controlled periodically:
Check / Clean
Weekly: wipe gently with a dry cloth (or
soaked in high purity isopropyl alcohol) or
clean it with dry air blowing
Clean / Replace
Every 3 months (according to the environ-
ment and frequency of use)
F-Theta scan lens cleaning procedure
Figure 1: Cleaning F-Theta scan lens
COMPONENT
TYPE OPERATION INTERVALS
F-Theta Scan Lens
Rack Air filter
CAUTION
Disconnect AC power cable before starting any maintenance operations.