background image

DSD-080 User Manual                                                                                    V-1.0

 

 

2

 

 

 

   

Any unauthorized use or copying of the contents or any part  of this document is 
prohibited. 

 
 

 

 

This document describes minimum requirements and necessary steps for the successful 
installation of the DSD-080 family units. 
Follow carefully advices given in the document. These are often good practices for the 
installation which reduce future issues. 
For all technical queries please contact Datakom at below e-mail address: 

[email protected] 

 
 

 

 

REVISION 

DATE 

WRITTEN 

DESCRIPTION 

01 

20.12.2016 

MH 

First edition 

 

 

 

 

 

CAUTION:

 Potential risk of injury or death.  

 

WARNING:

 Potential risk of malfunction or material damage. 

 

ATTENTION: 

Useful hints for the understanding of device operation. 

 

TERMINOLOGY

 

 

REVISION HISTORY

 

 

ABOUT THIS DOCUMENT

 

 

COPYRIGHT NOTICE

 

 

Summary of Contents for DSD-080

Page 1: ...with a battery backup 24V 1 2A h batteries are incorporated to the unit The unit provides automatic battery charging feature During long mains failures if batteries get low the unit gives audible and...

Page 2: ...ument These are often good practices for the installation which reduce future issues For all technical queries please contact Datakom at below e mail address technical support datakom com tr REVISION...

Page 3: ...ust be connected to phase voltage inputs in close proximity of the unit Fuses must be of fast type FF with a maximum rating of 6A Disconnect all power before working on equipment When the unit is conn...

Page 4: ...N 2 3 ELECTRICAL INSTALLATION 2 4 INSTALLATION DIAGRAM 3 PUSHBUTTON FUNCTIONS 4 DISPLAYS 5 ALARMS 6 DEVICE CONFIGURATION 6 1 ENTERING THE PROGRAM MODE 6 2 CHANGING PARAMETER VALUE 6 3 LIST OF PARAMETE...

Page 5: ...lugs to their sockets Otherwise you may destroy the socket and connector Be sure that the ambient temperature will not exceed the maximum operating temperature limit Below conditions may damage the de...

Page 6: ...DSD 080 User Manual V 1 0 6 Dimensions 192x120x65mm WxHYxD Weight 1900g 2 INSTALLATION 2 1 DIMENSIONS 192mm...

Page 7: ...DSD 080 User Manual V 1 0 7 The unit is designed for wall mounting Please mount on a flat surface through screw openings 2 2 MECHANICAL INSTALLATION WALL...

Page 8: ...nected to phase voltage input in close proximity of the unit Fuses must be of fast type FF with a maximum rating of 6A Use cables of appropriate temperature range Use adequate cable section at least 0...

Page 9: ...DSD 080 User Manual V 1 0 9 2 4 CONNECTION DIAGRAM...

Page 10: ...arm relay are reset Used to navigate between menus Programming mode Increase related value Used to navigate between menus Programming mode Decrease related value HELD PRESSED TOGETHER FOR 3 SECONDS En...

Page 11: ...it is operating normally BATTERY NORMAL LED Indicates that the battery voltage is above the Low Battery Voltage parameter LOW BATTERY LED Indicates that the battery voltage is below the Low Battery Vo...

Page 12: ...ay outputs become active and the unit gives an audible alarm By depresing the RESET pushbutton alarms are reset and relays return to their initial position ALARM MESSAGE DESCRIPTION LOW BATTERY Occurs...

Page 13: ...e memory and are not affected by energy failures In program mode the required parameter is selected using or pushbuttons By depressing the pushbutton the parameter modification is enabled Using and pu...

Page 14: ...e LOW BATTERY Output closed when battery is low WEAK MOTION Output closed during a weak motion WEAK MOTION LATCHED Output closed during a weak motion Remains closed until manually reset WEAK MOTION SO...

Page 15: ...r 4W maximum Battery charge voltage 27 5V 0 2V Battery charge current 100mA maximum Low battery voltage limit 22V 0 3V Current drain from battery 15mA max from 24VDC All relays passive Additional 6mA...