all defined global variables are shown with the supplied values. It is not
possible to change the values.
Double input
defines the period of time one has to wait before
the card can be read again. The range of permitted values is from 0 to 65499. You can define
the display duration of the function "‘confirm"’ via
demand timer
. The range of permitted
values is from 0 to 255. The parameter
recordf illlevel
displays the percentage of the capacity
utilisation of the memory of the terminal.
communication
First there will be an inquiry with
break communication
?
. If you confirm with ENTER, the
communication will be broken. You can detect an interruption of the communication in the toolbar
when only the PZE-MasterIV symbol is displayed on the left and all other fields are empty.
interface
Here it is possible to select the communications (RS232 or TCP/IP) via the arrow keys and to
confirm the selection with ENTER. Each communication has different parameters which have
to be set if necessary. You can find further descriptions of the parameters in chapter
baud-rate
You can select 9600, 19200 or 38400 as baud-rates.
timeout[100]
Here you can select a period of time for the communication in ms that constitutes the waiting
time till the output of an error message. The range of values is between 100 and 2000. The
input will be rounded down to 10.
TCP/IP
Not all displayed values can be changed. You can find a further description of the parameters
in chapter
If you press the ESC-key the device switches back to the bios menu.
display/buzzer
Here you can set the optical and acoustic values of the device.
LCDlighting
You can choose between low, middle and high for the backlight.
LCDcontrast
Is display contrast is set by a value between 0 and 100.
buzzer
The warning tone can be set low or loud. werden.
date&time
You can set date and time here as well as the automatic change from summertime to wintertime.
3.6 Communications
The PZE-MasterIV Basic has different interfaces for communication (dependent on features and hardware
version). Thus, peripheral (e.g. bar code- or transponder reader) can be connected to the device or a
communication with the device is possible. The configuration can partly be done at the device, e.g. change
the communication and set the baud rate. Further configuration can only be done via the DatafoxStudioIV
for safety reasons, e.g. GPRS configuration.