3.4.
Mounting outdoors
3.4.1. Degree of protection
The terminal EVO 4.3 has IP65 on the front side.
On the backside, only the cable feed / connection area is a restriction with respect to the IP class. If
the device is mounted on a flat base, the connection area is protected so that the entire system has
IP65
3.4.2. Temperature
The device has an approved temperature range of - 20 ° C to + 70 ° C.
A heater is not necessary for outdoor use.
Due to the inherent heat of the electronics and power supply, the temperatures in the unit are higher
even at ambient temperatures below -20 ° C.
Condensation water only occurs when a cold object comes into the heat and would therefore only
be an issue for mobile devices.
We recommand, if you use the devices outsite, then let it running permanently. Both in terms of
temperature as well as condensation, it is recommended to not switch off devices which are used
outdoors.
View recessed
Installation in
A front plate /
Mounting plate
.
The connection area is set up to the top of the apparatus,
so that no water coming from above (e.g., rain) could
penetrate. Only jet water from below would be a problem.
Should additional conditions beyond the normal weather
cause the water to come from below, the terminals can
be sealed to the wall when mounting.
For the EVO terminals it is advisable to mount the units
on the heel of the front shell.
This would sink the entire back of the device with the
connections and in the inaccessible area.
In order to allow such mounting, a mounting surface must
be provided by the customer. For example, In boxes with
front panel.
In the case of bell systems / mailboxes / barriers, mount-
ing plates are usually already available which can be
used for this purpose.