14
DataDirect Networks StorageScaler 6000 User Guide Rev B
2.2 Enclosure Installation Procedures
Warning
The StorageScaler 6000 Enclosure with all its component parts installed is too heavy for a single
person to easily install into a Rack cabinet.
Caution
Ensure that you have fitted and checked a suitable anti-static wrist or ankle strap and observe all
conventional ESD precautions when handling StorageScaler 6000 modules and components. Avoid
contact with Backplane components and module connectors, etc.
Note
StorageScaler 6000 enclosures are supplied and delivered populated with Backplane, Baseplane, Front
Panel, DEMs, and with PCMs installed. The Drive Carrier Modules are supplied as a separate package.
The StorageScaler 6000 enclosure is in compliance with EIA-310-D “Cabinets, Racks, Panels, and
Associated Equipment”. The enclosure is designed to fit within a 4U rack space. A typical rack mounting
installation in shown in
Figure 2–4
.
2.3 I/O Module Configurations
2.3.1 Controller Options
The StorageScaler 6000 has a standard SAS JBOD IO controller, which employs a 36-port expander with
zoning. The zoning is implemented via a preset piano-switch located on the enclosure baseboard. Host
ports 1 and 2 present drives 1 through 30 and host ports 3 and 4 present drives 31 through 60. Each host
port responds with drive information applicable only to the drives presented on the respective zone and
enclosure status information for the entire enclosure.
Figure 2–4
Full Rack without 9900 controllers.
USO