1.5 Environment
The enclosure and all of its sub-components are compliant to the European Union RoHS (Restriction of
Hazardous Substances) Directive (Directive 2002/95/EC) with no exceptions or exemptions.
Table 1–4
Display Panel LEDs
ICON
LABEL
COLOR
Definition
Normal Behavior
Shelf
Identify
(Note 1)
Note 1: not currently implemented
AMBER
Enclosure Identify
ON
-SES is sending an Identify
command.
OFF
-SES is NOT sending an Identify
command
System Fault
AMBER
Enclosure Fault
ON
-one or more components within
enclosure have failed. A service action is
required. Exact failed component has its
own amber fault LED lit.
OFF
-no detectable faults
System Power
GREEN
Enclosure Powered
ON
ON
- DC power is present
OFF
- DC power is NOT present
LED does NOT flash under normal
operating conditions.
Cover Open
AMBER
Enclosure cover is
open
OFF
-both cover pieces securely closed
and latched in place.
ON
-either of the cover pieces is NOT
securely closed and latched in place
Note:
The baseplane incorporates an Audible Alarm. This alarm is used to indicate a “cover open”
condition. To silence alarm, close the cover.
DEM Fault
(Note 2)
Note 2: not currently implemented
AMBER
DEM fault
OFF
-all DEMs operating correctly.
ON
-at least one DEM has failed; service
action required
Drive Fault
(Note 3)
Note 3: not currently implemented
AMBER
Drive fault
ON
-one or more HDDs are faulted. SES
must determine exact HDD.
OFF
-no detectable drive faults
Individually
numbered
HDDs
GREEN
HDD activity
ON
-indicates HDD activity
OFF
-no HDD activity