System Installation and Configuration
96-30051-001 Rev. D3
DDN SFA12K (SFA OS 2.3.1) Hardware Installation & Configuration Guide | 23
8.
Configuring the ATSs
NOTE :
You must configure the ATSs’ Line VRMs and voltage transfer range
values for use at your site before powering up the SFA12K system.
8.1
Access the Web Interface
The SFA12K family dedicated ATSs are factory configured with a default IP address (see
). It is recommended that the ATS network interfaces be used only for initial setup.
Refer to the
SFA OS User Guide
for information on how to display the current network
interface settings on the ATS.
NOTE :
It is recommended that the ATS remains disconnected from any
management networks after initial setup unless you plan on monitoring
it with event notifications as outlined in the
SFA OS User Guide
.
1.
Temporarily unplug the controllers’ and BBUs’ power cables from the ATSs as shown
in
and
To ensure that the BBUs and controllers remain powered off during ATS
configuration, it is important to completely remove the power source.
Warning
!
Controller
Figure 13. Disconnect Power Cables from ATS (with BBU Model 5P1550GR)
Unplug
these two
power
connectors
BBU
Model 5P1550GR
ATS
BBU
ATS
Figure 14. Disconnect Power Cables from ATS (with BBU Model 1550)
Controller
Unplug
these two
power
connectors
Model 1550