Chapter 15. Technical Specifications
15.1. Environmental Conditions
Operating Temperature: 0 to 50 degrees Celsius
Storage Temperature: -20 to 65 degrees Celsius
Humidity: 10 to 90% non condensing
15.2. Power Suply and Consumption
DC: 36 to 72 V for all dispositives
15.2.1. Power
Interface Board: 21A
MPU: 3A
Multipurpose: 3A
FAN Board: 3A
Fastons: 20A each, total 40A
15.3. Dimensions
Height
240 mm (DM4004), 400mm (DM4008) and 44mm (DM4001)
Width
440mm without L brackets to install in 19” rack
483mm with L brackets to install in 19 ” rack
Depth
280 mm (DM4004, DM4008 and DM4001)
43
Summary of Contents for DM4001
Page 1: ...DM4000 Series Installation and Operation Guide 204 0112 00...
Page 2: ...Revision History Revision 0 0 2007 10 22 First version...
Page 7: ...16 Norms and Certifications 45 16 1 Norms 45 A DB9 46 A 1 Pins 46 vii...
Page 19: ...Chapter 4 DM4008 Chassis 4 3 Rear Panel Description Figure 4 3 DM4008 Chassis Rear Panel 10...
Page 23: ...Chapter 5 DM4000 MPU192 AUX Port 2 Tx 6 Rx 14...
Page 27: ...Chapter 6 DM4000 MPU384 AUX Port 2 Tx 6 Rx 18...