Chapter 5. DM4000 MPU192
LED
CONDITION
STATUS
OFF
Indicates that a 100M inactive.
Link Act
ON/Blinking
Connection established.
OFF
No connection established.
5.4. Console and Ethernet Outband Management Ports
The DM4000 MPU192 contains three RJ-45 connectors on its front panel. One for Outband Management
a console port and a AUX console Port for future implementation.
The Management interface can be connected to a desktop throught a CAT 5 ethernet cable and the console
cable pinout to a standard DB9 connector can be found in the appendice A.
The pin-out of both console and outband management ports are shown in the next figure.
Figure 5-4. DM4000 MPU192 - Front Panel Conectors
Table 5-2. Interface Pinout
Management Port
RJ-45
Signal
1
Tx+
2
Tx-
3
Rx+
6
Rx-
4,5,7,8
-
RJ-45 Serial Port
3
Tx
6
Rx
13