Initial Configuration
23
© 2009 Datacom Systems Inc
4.1.4.5
SET IP (SE IP), SUBNET (SU), GATEWAY (GA)
This command configures the IP address (default 192.168.1.1), Subnet Mask (default
255.255.255.0) and Default Gateway (default 0.0.0.0) parameters. Initially, it is highly
recommended that this be done through the direct serial connection using the HyperTerminal or
equivalent terminal emulation application. Only those variables that require configuration need to be
entered.
The parameters may be entered separately as shown:
# SET IP (SE IP) [IP Address nnn.nnn.nnn.nnn] [SUBNET] [GATEWAY]
# SET SUBNET (SE SU) [Subnet Mask nnn.nnn.nnn.nnn]
# SET GATEWAY (SE GA) [Default Gateway nnn.nnn.nnn.nn*n]
Example: # SE IP 172.169.50.134
IP will be updated at end of session
# SE SU 255.255.0.0
Subnet Mask will be updated at end of session
# SE GA 172.169.50.1
Default Gateway will be updated at end of session
#
Or, the parameters can also be entered jointly, (i.e., IP Address, Subnet Mask, Default Gateway)
but entry must be in the proper sequence order and separated by a space delimiter, as shown:
# SET IP [SUBNET] [GATEWAY]
Example: # SE IP 172.169.50.134 255.255.0.0 172.169.50.1
IP will be updated at end of session
Subnet Mask will be updated at end of session
Default Gateway will be updated at end of session
#
4.1.4.6
SET DATE (SE DA)
This command, followed by the date (MMDDYY), sets the real time clock date as shown:
SET DATE (MMDDYY)
Example: # SE DA 123107
#
Summary of Contents for VS-1200 Series
Page 2: ......
Page 12: ......
Page 42: ......
Page 46: ...VS 1200 Data Acccess Switch 46 2009 Datacom Systems Inc VS 1204BT VS 1204SFP ...