Color Target – the value that you specified earlier as the desired white color (White
Point) to calibrate the monitor to (in CIE xy)
Current – the current measured white color (in CIE xy)
Difference – the difference between the Target and the Current color values expressed
in Delta ab. A difference of zero means that the monitor is adjusted to exactly the
desired white color. The monitor setting is close enough if the difference is less than
0.5
Kelvin Target – the value that you specified earlier as the desired white color (White
Point) to calibrate the monitor to (in degrees Kelvin)
Current – the current measured white color (in degrees Kelvin)
Luminance Target – if Measured Luminance Mode has been specified then this will
show the desired White Luminance value that was entered for the calibration
Current – the current measured White Luminance in candelas per meter squared