Supported Device Driver Capabilities
35
3
3
3
3
3
3
3
3
3
Range of Internal Input Clock Frequency, in Hz
OLC_FG_IC_CLOCK_FREQ_LIMITS
Fixed
50 Hz: 15,000,000
60 Hz: 12,500,000
Clock Sources
OLC_FG_IC_CLOCK_SOURCE_LIMITS
Supports Internal Clock
OLC_FG_CLOCK_INTERNAL
Supports External Clock
OLC_FG_CLOCK_EXTERNAL
Yes
No
Provides Trigger
OLC_FG_IC_DOES_TRIGGER
Yes
Trigger Types
OLC_FG_TRIGGER_TYPE_LIMITS
Supports Externally Triggered Acquisition
OLC_FG_TRIG_EXTERNAL_LINE
Yes
Multiple Trigger Types
OLC_FG_IC_MULT_TRIGGER_TYPE_LIMITS
Supports Externally Triggered Acquisition
OLC_FG_TRIG_EXTERNAL_LINE
Yes
Multiple Trigger Modes
OLC_FG_IC_MULT_TRIGGER_MODE_LIMITS
Trigger Starts Multiple Frame Acquisition
OLC_FG_MODE_START
Trigger Starts Each Frame Acquisition
OLC_FG_MODE_EACH
Yes
Yes
Supports Strobing
OLC_FG_IC_DOES_STROBE
No
Table 4: Input Signal Capabilities for the
DT3120 Device Driver (cont.)
Capability
DT3120 Support