Precauciones de Seguridad
Safety Precautions

Cajas acústicas activas / Self-powered loudspeaker enclosures
(VANTEC-20A, VANTEC-118A)

The exclamation point inside an equilateral triangle is intended to 
alert  the  users  to  the  presence  of  important  operating  and 
maintenance  (servicing)  instructions  in  the  literature 
accompanying  the  product.  Heed  all  warnings.  Follow  all 
instructions. Keep these instructions.
WARNING: This is a class A product. In a domestic environment 
this product may cause radio interferences in which case the user 
may be required to take adequate measures.
Use this product only in E1, E2, E3 or E4 environments according 
to EN55103-2.

Equipo  diseñado  para  funcionar  entre  15ºC  y  45ºC  con  una 
humedad relativa máxima del 95%, con un rango de ±10% de la 
tensión nominal de alimentación indicada en la etiqueta trasera 
(según IEC 60065). Si debe sustituir el fusible preste atención al 
tipo y rango.

Working  temperature  ranges  from  15ºC  to  45ºC  with  a  relative 
humidity  of  95%,  with  ±10%  of  the  rated  main  voltage  value 
indicated on the rear label (according to IEC 60065). If the fuse 
needs  to be replaced,  please  pay attention  to correct  type and 
ratings.

No  instale  el  aparato  cerca  de  ninguna  fuente  de  calor  como 
radiadores, estufas u otros aparatos que produzcan calor. Debe 
instalarse siempre sin bloquear la libre circulación de aire por las 
aletas del radiador.

Do  not  install  near  any  heat  sources  such  as  radiators,  heat 
registers,  stoves  or  other  apparatus  that  produce  heat.  The 
circulation of air through the heatsink must not be blocked.

No  exponga  este  equipo  a  la  lluvia  o  humedad.  No  use  este 
aparato  cerca  del  agua  (piscinas  y  fuentes,  por  ejemplo).  No 
exponga el equipo a salpicaduras ni coloque sobre él objetos que 
contengan líquidos, tales como vasos y botellas. Equipo IP-20.

Do  not  expose  this  device  to  rain  or  moisture.  Do  not  use  this 
apparatus  near  water  (for  example,  swimming  pools  and 
fountains). Do not place any objects containing liquids, such as 
bottles or glasses, on the top of the unit. Do not splash liquids on 
the unit. IP-20 equipment.

No  emplace  altavoces  en  proximidad  a  equipos  sensibles  a 
campos  magnéticos,  tales  como  monitores  de  televisión  o 
material magnético de almacenamiento de datos.

Do  not  place  loudspeakers  in  proximity  to  devices  sensitive  to 
magnetic  fields  such  as  television  monitors  or  data  storage 
magnetic material.

Este  símbolo  indica  que  el  presente  producto  no  puede  ser 
tratado  como  residuo  doméstico  normal,  sino  que  debe 
entregarse en el correspondiente punto de recogida de equipos 
eléctricos y electrónicos.

This symbol on the product indicates that this product should not 
be treated as household waste. Instead it shall be handed over to 
the appicable  collection  point  for the recycling  of electrical  and 
electronic equipment.

El  cableado  exterior  conectado  al  equipo  requiere  de  su 
instalación por una persona instruida o el uso de cables flexibles 
ya preparados.

The outer wiring connected to the device requires installation by 
an  instructed  person  or  the  use  of  a  flexible  cable  already 
prepared.

Si  el  aparato  es  conectado  permanentemente,  la  instalación 
eléctrica del edificio debe incorporar un interruptor multipolar con 
separación de contacto de al menos 3mm en cada polo.

If the apparatus is connected permanently, the electrical system 
of  the  building  must  incorporate  a  multipolar  switch  with  a 
separation of contact of at least 3mm in each pole.

El colgado del equipo sólo debe realizarse utilizando los herrajes 
de colgado recomendados y por personal cualificado. No cuelgue 
la caja de las asas.

The appliance should be flown only from the rigging points and by 
qualified personnel. Do not suspend the box from the handles.

Limpie con un paño seco. No use limpiadores con disolventes.

Clean  only  with  a  dry  cloth.  Do  not  use  any  solvent  based 
cleaners.

No existen partes ajustables por el usuario en el interior de este 
equipo.  Cualquier  operación  de  mantenimiento  o  reparación 
debe  ser  realizada  por  personal  cualificado.  Es  necesario  el 
servicio  técnico  cuando  el  equipo  se  haya  dañado  de  alguna 
forma, como que haya caído líquido o algún objeto en el interior 
del aparato, haya sido expuesto a lluvia o humedad, no funcione 
correctamente,  haya  recibido  un  golpe  o  su  cable  de  red  esté 
dañado.

No user serviceable parts inside. Refer all servicing to qualified 
service personnel. Servicing is required when the apparatus has 
been damaged in any way, such as power-supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally or has been dropped.

Para  las  cajas  con  vaso  para  trípode,  la  altura  máxima  de 
seguridad  desde  el  suelo  a  la  base  de  la  caja  montada  sobre 
trípode modelo TRD-2, con pies a 55 cm del eje del trípode, es:

For  enclosures  with  tripod  socket,  the  maximum  safety  height 
from  floor  to  bottom  of  enclosure  when  mounting  on  a  TRD-2 
tripod, with legs spread 55cm from the central pole, is:

El  signo  de  exclamación  dentro  de  un  triángulo  indica  la 
existencia  de  importantes  instrucciones  de  operación  y 
mantenimiento en la documentación que acompaña al producto.
Conserve y lea todas estas instrucciones. Siga las advertencias.
ATENCIÓN:  Es  un  producto  clase  A,  por  lo  que  en  entornos 
domésticos puede causar radio-interferencias, en cuyo caso el 
usuario tendrá que tomar las medidas oportunas.
De acuerdo con EN55103-2, usar el equipo sólo en entornos E1, 
E2, E3 ó E4.

55 cm

 

VANTEC-20A ------------->150 cm

Para  desconectar  el  dispositivo  debe  usar  el  enchufe. 
Desconecte  este  aparato  durante  tormentas  eléctricas, 
terremotos  o  cuando  no  se  vaya  a  emplear  durante  largos 
periodos.

To disconnect the device, you should use the mains plug. Unplug 
this  apparatus  during  lightning  storms,  earthquakes  or  when 
unused for long periods of time.

No desconecte la tierra en el conector de alimentación pues es 
peligroso  e  ilegal.  Equipo  de  Clase  I.  El  producto  debe  ser 
conectado a un enchufe con toma de tierra. Sólo use este equipo 
con el cable de red de alimentación adecuado para su país.
El signo del rayo con la punta de flecha, alerta contra la presencia 
de  voltajes  peligrosos  no  aislados.  Para  reducir  el  riesgo  de 
choque eléctrico, no retire la cubierta.

Do  not  remove  mains  connector  ground,  it  is  dangerous  and 
illegal. Class I device. The product must be connected to a mains 
socket  outlet  with  protective  earth  connection.  Only  use  this 
equipment with an appropriate mains cord for your country.

The lightning and arrowhead symbol warns about the presence of 
uninsulated  dangerous  voltage.  To  reduce  the  risk  of  electric 
shock, do not remove the cover.

 

VANTEC-20A ------------->150 cm

Manual del Usuario / vantec series / User’s Manual

Summary of Contents for Vantec-118A

Page 1: ...tes de utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ...

Page 2: ...io vantec series User s Manual INTRODUCTION LINE DRAWINGS 3 4 5 11 11 24 12 18 19 23 AMPLIFIERS SPECIFICATIONS RIGGING SYSTEM ANNEX Description ON OFF Overload indicator Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS Troubleshooting Line connections unbalanced and balanced SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY ...

Page 3: ...o If the apparatus is connected permanently the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole El colgado del equipo sólo debe realizarse utilizando los herrajes de colgado recomendados y por personal cualificado No cuelgue la caja de las asas The appliance should be flown only from the rigging points and by qualifie...

Page 4: ...aración en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authori...

Page 5: ...io video and similar electronic apparatus Safety requirements l EN 55032 2012 Electromagnetic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of e...

Page 6: ...ic birch plywood and finished with the DAS ISO flex coating Power is supplied by a cutting edge 1500 Wpeak Class D amplifier in a biamplified configuration driving a single DAS 12F4C loudspeaker and twin M 60 compression drivers Features The VANTEC 20A and VANTEC 118A powered multifunction systems combine DAS s reputation for performance and reliability with the latest technological innovations of...

Page 7: ...R Accessories 2 TRD 6 Stacking bracket for VANTEC 218A max 4 u max 1 u using TRD 6 TRD 2 black Speaker cabling SC 2 2m XLR microphone signal balanced cable 2 Units 2 x VANTEC 20A 2 x VANTEC 218A Manual del Usuario vantec series User s Manual ...

Page 8: ...k Speaker cabling SC 1 1m XLR microphone signal balanced cable 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 4 6 x VANTEC 20A 2 x VANTEC 118A Manual del Usuario vantec series User s Manual 2 PL VT20S Steel transport dolly for VANTEC 20A max 4 u black 1 PL VT118S Wooden transport dolly for VANTEC 118A max 2 u black ...

Page 9: ...NTEC 20A max 5 u black Speaker cabling SC 1 1m XLR microphone signal balanced cable 4 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 4 2 PL VT20S Units Processors 1 DSP 2060A 2 In 6 Out fully configurable DSP 9 full bandwidth parametric band EQ on each channel AudioCore DASnet equipped Manual del Usuario vantec series User s Manual ...

Page 10: ...R microphone signal balanced cable 6 PWCONLINK 09 0 9m powerCON jumper NAC3FCB cable 6 Units Processors 1 DSP 2060A 2 In 6 Out fully configurable DSP 9 full bandwidth parametric band EQ on each channel AudioCore DASnet equipped POWER POWER 2 PL VT20S 2 PL VT118S 6 x VANTEC 20A 4 x VANTEC 118A Manual del Usuario vantec series User s Manual ...

Page 11: ... series User s Manual 1500 Wpeak Class D Bi amp Balanced Differential Line Line 20kOhms Line 3 V 12dBu 63 Hz 20 kHz 90º Nominal 15º Nominal 135 dB LF 1 x 12F4C GM 12F4 HF 2 x M 60 GM M60N Trapezoidal 7 5º Birch Plywood Black ISO flex Paint Integrated in box design INPUT 1 x Female XLR LOOP THRU 1 x Male XLR AC INPUT 1 x PowerCon AC OUTPUT 1 x PowerCon 3 0A 115V 50 Hz 60 Hz 1 5A 230V 50 Hz 60 Hz 33...

Page 12: ...sing THRU HPF 3 LIMIT Red LED indicates amplifier saturation Amplifier limiter indicator lights 4 SIGNAL Green LED indicates signal presence 5 ON Green LED indicates that the unit is ON 6 SUB LEVEL Potentiometer for adjusting the unit level 7 AC INPUT Standard PowerCon NAC3FCA mains connector inserted rotated and locked for ON Only use this equipment with an appropriate mains cord 8 THRU HPF SATEL...

Page 13: ...he array Rotate the encoder to select the option needed and press again to confirm Use the same Number Of Units IN ALL the cabinets of your system Once the input source has been connected to the amplifer s cabinet the user has to check the gain structure of the system Adjust level output from your processor and or mixing console in order to prevent INPUT CLIP left signal meter As well try to avoid...

Page 14: ... HPF off HPF off THROW Mid Press the encoder Rotate the encoder and press to confirm one of the following HPF options off 63Hz V118A 100Hz User MUST enable the SAME HPF in ALL cabinets forming the array In order to have more dynamic headroom in the system when used with subs HPF at V118A position with Vantec subwoofers or 100Hz is highly recommended Press the encoder and rotate it until THROW is s...

Page 15: ...AVE R mode connection Select Mode SINGLE L R MASTER L DASlink MASTER L CONTINUE Wait a minute SLAVE R SINGLE Mode Master Slave Adding Slave Unit CREATE NEW LINK Select Mode SLAVE R CREATE NEW LINK CREATE NEW LINK Waiting MASTER Searching for SLAVE connection Altea unit Wait a minute Wait a minute Master cabinet Master cabinet Master cabinet Master cabinet Only Wireless Audio Wireless Audio Control...

Page 16: ... B User can LOCK the Display and the encoder WITH PASSWORD by enabling this option MENU LOCK pw292 In case A to unlock just press the encoder In case B to unlock PUSH encoder and enter the 3 digit password 292 STAND BY When no signal is detected the amplifer shuts down Time can be selected OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIONS MENU OPTIO...

Page 17: ... for several seconds after the mains power has been disconnected Low mains voltage If mains voltage falls below the shutdown voltage for the unit it will stop playing When acceptable levels are regained the unit will switch back on automatically Therefore the current consumed by a 115V version is double the 230V version to achieve the same acoustic power level Normally it is enough just to let the...

Page 18: ...hase 1 Move the audio signal cable away from lighting cables Try to find out at what point the noise is leaking into the system 2 Connect the sound system to a different phase than the lights You may need the help of an electrician 1 Read the appendix of this manual to make a correct unbalanced to balanced cable 2 Connect the mixer and the unit to the same mains outlet 3 Use a cable that is as sho...

Page 19: ...g set up and teardown Only experienced installers with adequate knowledge of the equipment and local safety regulations should fly speaker boxes It is the user s responsibility to ensure that the systems to be flown including flying accessories comply with state and local regulations The working load limits in this manual are the results of tests by independent laboratories It is the user s respon...

Page 20: ...NTEC 118A as VANTEC 118A and VANTEC 20A Moving the lower trigger up 1 reveals the slide that will fall by its own weight 2 When releasing the trigger it will return to its place and the slide will remain fixed 3 Similarly to hide the slide we must act on the trigger as in 1 and push the slide up 4 releasing the trigger 3 finally Now if we attach this enclosure to another VANTEC 20A we will hear a ...

Page 21: ... a maximum of 5 units of VANTEC 20A It has 11 hook points for the lifting slings numbered from front to back see attached figure To assure the vertical inclination of the entire column use the Ease Focus software which will indicate which holes have to be used This frame will be joined to the first box of the column as if it were another enclosure and will be locked when a clack is heard The other...

Page 22: ...ide that allows a box angle between 25º and 10º when placed on a TRD 2 tripod or on a TRD 6 pole It is only possible to use one unit in this way The VANTEC 118A and VANTEC 218A enclosures have a socket for aTRD 6 pole 25º 7 5º 10º TRD 6 TRD 6 TRD 2 VANTEC 218A Example of VANTEC 20A on VANTEC 218A with TRD 6 VANTEC 20A ...

Page 23: ...nd the platform The other boxes will be joined by interlocking PL VT118S The platform PL VT118S with WLL 150 kgf allows transport of up to 3 stacked units of VANTEC 118A It is necessary to be very careful when moving the assembly since the enclosures are not fastened by interlocking to the platform although one VANTEC 118A can be interlocked with another since they have slides equal to those of th...

Page 24: ...ed by the shield affects both signal conductors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the re...

Page 25: ...8 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...

Reviews: