DARKSTAR TECHNOLOGIES T Spanner T1 Manual To Operation Download Page 4

Rev. 2/14/04

  

Specifications

Compliance

ANSI T1.403, T1.231, T1.408
AT&T TR54016, TR62411

Verifies

T1 carrier (1.544 Mbit/sec)
SF (D4) and ESF framing, AMI and B8ZS
line coding, Data detection, Signal level
(0 to -37.5 dB)

Error Detection

LOS (red alarm), AIS (blue alarm),
RAI (yellow alarm), Line code violations
(bipolar violations, excessive zeros),
Path code violations (D4 frame bit errors,
ESF CRC errors)

CSU Emulation

Sends RAI (yellow alarm) upon LOS, OOF
or AIS, Responds to CSU loop-up and
loop-down codes

Power Requirement

9-volt lithium (recommended) or 9-volt
alkaline battery

Dimensions

3.6 X 5.75 X 1.3 inches
9.1 X 14.6 X 3.3 centimeters

Shipping Weight

1 lb  or  0.45 kg

Operating Temperature

0 to 45 degrees centigrade
Non-condensing

User Interface

Single pushbutton Autotest!
2 X 16 LCD display
Six status leds & audio beeper

Media Access

Single RJ48C connector
Transient & over-current protection by Teccor

  

Assistance

Customer support is obtained through the distributor from which you purchased
your tester.  If you encounter problems or cannot locate your distributor, you may
reach us via fax at (765) 497-3337 or via our website at:

www.darkstartechnologies.com

  

Warranty

Darkstar Technologies warrants its products against defects in materials or
workmanship for a period of one year from the date of purchase.  Any product
that is returned shipping prepaid will be inspected and tested, and items meeting
warranty conditions will be repaired or replaced free of charge.  Please contact
your distributor if repair or replacement is required.

Summary of Contents for T Spanner T1

Page 1: ...afayette IN 47996 United States of America T1 Service Verifier DARKSTAR TECHNOLOGIES TIME LCV PCV 013 07 000 000 T Spanner TM O N O F F D 6 3 0 D A R K S T A R T E C H N O L O G I E S CARRIER DETECT FRAMING DATA DETECT ALARM LOOPED UP ERROR ...

Page 2: ...ivate the 630 and begin testing If you see a BATTERY IS LOW message at any time then simply replace the 9 volt battery in the rear of the housing You should be connecting to the telephone network using a straight through cable but you can also use the 630 to verify the operation of a CSU DSU by using a crossover cable The 630 will let you know if your cable appears to be properly connected to a T1...

Page 3: ...e D630 It s not unusual to see this when you first connect Looped Up means that the D630 received and responded to a CSU loop up code from the telco and will remain looped until a it receives the loop down code or b an LOS condition occurs or c an AIS alarm is received Error simply means that the LCV count and or the PCV count is non zero These counters are cleared each time the D630 goes out of f...

Page 4: ...ating Temperature 0 to 45 degrees centigrade Non condensing User Interface Single pushbutton Autotest 2 X 16 LCD display Six status leds audio beeper Media Access Single RJ48C connector Transient over current protection by Teccor Assistance Customer support is obtained through the distributor from which you purchased your tester If you encounter problems or cannot locate your distributor you may r...

Reviews: