Line Code Violations (LCV) are either bipolar violations or excessive zero
violations.

Path Code Violations (PCV) are either frame bit errors in the case of SF (D4)
framing or CRC errors in the case of ESF framing.

The led indicators above the LCD are there to show you the status of the T1 circuit
at a glance, while the display is used to provide more detailed information.  The
exact meaning of a particular led being lit can be summarized as follows:

Carrier Detect

 means that a T1 clock has been detected on the receive pair.

Framing

 means that the received T1 carrier is framed (either SF or ESF).

Data Detect

 means that the data within the received frames is neither all ones nor

all zeros.  In other words, it indicates the presence of payload data inside the
framed carrier.

Alarm

 means that one of the following conditions exists.

- LOS (loss of signal) simply means that the D630 is not receiving any T1 carrier.
This is one of the conditions referred to as a Red Alarm.

- AIS (Blue Alarm) means that unframed ones are being received.  In general, this
means that the upstream device is looped up or is off line.

- RAI (Yellow Alarm) will be received by the D630 if the telco does not see the T1
carrier sent from the D630.  It’s not unusual to see this when you first connect.

Looped Up

 means that the D630 received (and responded to) a CSU loop-up code

from the telco and will remain looped until (a) it receives the loop-down code or
(b) an LOS condition occurs or (c) an AIS alarm is received.

Error

 simply means that the LCV count and / or the PCV count is non-zero.  These

counters are cleared each time the D630 goes out of frame or is unplugged.

NOTE:

 

 

The T-Spanner automatically determines the line coding by detecting the

B8ZS code words in the received data.  If insufficient consecutive zeros are
present to cause a B8ZS code word substitution, then the line coding cannot be
determined.  In this case, the T-Spanner will assume AMI line coding for SF (D4)
framing and B8ZS line coding for ESF framing.

NOTE:

 The D630’s audible alert uses the following scheme to call your attention to

any alarm or fault condition, a status change or a new LCD message.

1 beep = mode change or new LCD message is up
2 beeps = any power related event
3 beeps = T1 fault or error message
4 beeps = D630 fault or error, such as a POST failure

NOTE:

 If the D630 is turned on but is not connected, it will go into a “low power”

mode and will eventually shut itself off, in order to conserve battery life.   When
the 630 is connected to a network, then it will stay on and continue testing
indefinitely until it is manually switched off or until it is disconnected.

Summary of Contents for T Spanner T1

Page 1: ...afayette IN 47996 United States of America T1 Service Verifier DARKSTAR TECHNOLOGIES TIME LCV PCV 013 07 000 000 T Spanner TM O N O F F D 6 3 0 D A R K S T A R T E C H N O L O G I E S CARRIER DETECT FRAMING DATA DETECT ALARM LOOPED UP ERROR ...

Page 2: ...ivate the 630 and begin testing If you see a BATTERY IS LOW message at any time then simply replace the 9 volt battery in the rear of the housing You should be connecting to the telephone network using a straight through cable but you can also use the 630 to verify the operation of a CSU DSU by using a crossover cable The 630 will let you know if your cable appears to be properly connected to a T1...

Page 3: ...e D630 It s not unusual to see this when you first connect Looped Up means that the D630 received and responded to a CSU loop up code from the telco and will remain looped until a it receives the loop down code or b an LOS condition occurs or c an AIS alarm is received Error simply means that the LCV count and or the PCV count is non zero These counters are cleared each time the D630 goes out of f...

Page 4: ...ating Temperature 0 to 45 degrees centigrade Non condensing User Interface Single pushbutton Autotest 2 X 16 LCD display Six status leds audio beeper Media Access Single RJ48C connector Transient over current protection by Teccor Assistance Customer support is obtained through the distributor from which you purchased your tester If you encounter problems or cannot locate your distributor you may r...

Reviews: