Darco ERO-32AP-0 V1.4 Instruction Manual And Warranty Card Download Page 13

ELECTRONIC MOTOR SPEED COTROLLER 

ERO-32AP-0 V1.4

EN

WARRANTY

DARCO Sp. z  o.o. gives warranty for proper functioning of the device according to technical and operation conditions mentioned in this 
instruction manual.

WARRANTY CONDITIONS

1.   Warranty period is 24 months starting from date of purchase.
2.   Warranty guarantees free of charge repairing of defects caused by imperfect parts of production failures.
3.   Warranty expires when damages are caused by the following:

a)   damages caused by improper connection of power or steering cables,
b)   damages caused by usage of power supply unit other than the one recommended by the producer,
c)   damages caused by improper transport or unloading,
d)   damages caused by fires, floods, thunderstorms or other acts of God,
e)   damages caused by improper mounting,
f)   unauthorized dismantling, remodeling, fixing or part replacing,
g)   normal exploitation parts or material stale.

4.   Customer has a right to replace the purchased good with a new one if it was already damaged two times and got broken for the third time.
5.   Vital condition for the Customer to fulfill the warranty is to bring the damaged product to the Seller along with:

a)   correctly filled warranty card,
b)   receipt of purchase.

 

Both Seller and Customer must assure that warranty card is filled out correctly and has at least: name and surname of the Customer or his company, 
address, purchase date, stamp and signature of the Seller.

6.   In cases not mentioned by these regulations, standard regulations apply. 

Declaration of performance:

DOP No 01/2021 from 26.01. 2021
Year of CE marking: 21

21

Summary of Contents for ERO-32AP-0 V1.4

Page 1: ...REGULATOR PR DKO CI OBROTOWEJ ERO 32AP 0 V1 4 INSTRUCTION MANUAL WARRANTY CARD ELECTRONIC MOTOR SPEED COTROLLER ERO 32AP 0 V1 4 PL EN 2021 03 DARCO Sp z o o POLAND 39 200 D bica ul Metalowc w 43 tel...

Page 2: ...przed monta em i przegl dem urz dzenia nale y bez wzgl dnie od czy napi cie zasilaj ce 3 Nie montowa urz dzenia w miejscach gdzie mog wyst powa wysokie temperatury powy ej 50 C 4 Nie montowa urz dzen...

Page 3: ...analogowego lub cyfrowego K1 numer ekranu informacyjnego K2 wybrany czujnik zewn trzny brak czujnika czujnik analogowy czujnik cyfrowy PL MENU Rysunek 3 Organizacja ekran w informacyjnych Wyboru aktua...

Page 4: ...zostaje uruchomione z pr dko ci obrotow r wn V minimum 0 55 C 1 2 2 V minimum Ustawianie minimalnej pr dko ci obrotowej urz dzenia sterowanego 0 50 1 2 3 T maksimum Ustawianie temperatury przy kt rej...

Page 5: ...analogowym czujnikiem temperatury typu PT1000 W menu 1 1 pojawia si dodatkowy tryb pracy czujnikowy z mo liwo ci konfiguracji w podmenu 1 2 cyfrowy wej cie CZUJNIK wsp pracuje z dowolnym czujnikiem wy...

Page 6: ...dzenia sterowanego 1 Nie dokonano wyboru typu urz dzenia sterowanego menu Ustawienia Typ urz dzenia 2 Awaria wewn trzna sterownika 0000 0001 0000 Brak komunikacji z czujnikiem temperatury pokojowej ry...

Page 7: ...wymiany cz ci bez zgody producenta g zu ycia cz ci i materia w w normalnym trybie eksploatacyjnym 4 Konsumentowi przys uguje prawo wymiany zakupionego wyrobu na nowy je eli wyr b by dwukrotnie naprawi...

Page 8: ...ng the controller to electrical power should be made only by a quali fied electrician 2 Every time before mounting conservation etc unplug the device from electrical power 3 Avoid installing device in...

Page 9: ...r K1 information screen number K2 selected external sensor no sensor analogue sensor digital sensor K3 selected working mode sensor mode fixed mode zone mode fixed sensor mode zone sensor mode EN MENU...

Page 10: ...2 digital zone sensing the rotation speed of the controlled device is constant during the given period and depends on parameters set in sub menu 1 4 but only when the sensor is active otherwise the de...

Page 11: ...logue temperature sensor PT1000 type An additional working mode sensor appears in menu 1 1 with the option to configure it in sub menu 1 2 digital the SENSOR inputsupportsanysensorprovidedwitharelay t...

Page 12: ...cted 1 No type of the controlled device was selected in menu Settings Device type 2 Internal controller malfunction 0000 0001 0000 No communication with the room temperature sensor fig 1 item 5 1 Inte...

Page 13: ...damages caused by fires floods thunderstorms or other acts of God e damages caused by improper mounting f unauthorized dismantling remodeling fixing or part replacing g normal exploitation parts or ma...

Page 14: ...ler stamp piecz stamp data sprzeda y purchase date data i podpis klienta date signature Zapozna em am si i akceptuj warunki gwarancji I have read and accepted the warranty conditions Kr tki opis uszko...