MENU

1

 Parameters

1.2.2

 V(minimum)

1.2.3

 T(maximum)

1.2.4

 V(maximum)

1.2.5

 Temp. Correct.

1.3.1

 Rotation speed

1.4.1

 Working days

1.4.2

 Saturdays

1.4.3

 Sundays

1.1

 Operating mode

1.2

 Sensor mode*

1.3

 Constant mode

1.4

 Zone mode

1.2.1

 T(minimum)

ANALOG SENSOR

DIGITAL SENSOR

EN

Figure 4 legend:

turning the knob right
turning the knob left
knob briefly pressed
knob pressed and held

* the screen is displayed only if one of the external sensors was selected

1. PARAMETERS

 

Parameter configuration of the controlled device regulator.

1.1  Operating mode 

Selection of working mode of the regulator:

sensing

 - the rotation speed of the controlled device depends on parameters 

set in sub-menu 1.2. This item is visible if the type of the external sensor 
was selected in menu 2.2 - “analogue”.

constant

 - the rotation speed of the controlled device is constant and 

depends on parameters set in sub-menu 1.3.

zoned

 - the rotation speed of the controlled device is constant during the 

given period and depends on parameters set in sub-menu 1.4.

const. sens.

 - the rotation speed of the controlled device is constant and 

depends on parameters set in sub-menu 1.3, but only when the sensor is 
active -  otherwise the device will be switched off. This item is visible if the 
type of the external sensor was selected in menu 2.2 - “digital”.

zone sensing

 - the rotation speed of the controlled device is constant during 

the given period and depends on parameters set in sub-menu 1.4, but 
only when the sensor is active -  otherwise the device will be switched off. 
This item is visible if the type of the external sensor was selected in menu 
2.2 - “digital”.

1.2 Sensor mode

 

Parameter configuration of the sensor mode of the regulator (this item is 
visible if the type of the external sensor was selected in menu 2.2).

If an external analogue sensor was selected:

1.2.1 T (minimum) 

- Temperature setting, at which the controlled device is 

switched on with a rotation speed equal to V(minimum). 
(0 ÷ +55°C)

1.2.2 V (minimum)

 - Minimum rotation speed setting of the controlled device. 

(0 ÷ 50%)

1.2.3 T (maximum)

 - Temperature setting, at which the controlled device 

reaches its maximum rotation speed equal to V(maksimum). 
(+60 ÷ +100°C)

1.2.4 V (maximum) 

- Maximum rotation speed setting of the controlled device. 

(50 ÷ 100%)

1.2.5 Temp. Correct. 

- Temperature correction setting of an external 

analogue sensor. 
(-30 ÷ +30°C)

If an external digital sensor was selected:

1.2.1 Output type

 

Selection of the output type of the external digital sensor.

 

NC - normally closed.

 

NO - normally open.

1.3 Constant mode

 

Parameter configuration of the fixed mode of the regulator.

1.3.1 Rot. speed

 - Rotation speed setting of the controlled device. 

(0 ÷ 100%)

1.4 Zone mode

  

Parameter configuration of the zone mode of the regulator.

1.4.1 Working days 

- Setting time zones used on working days.

 

S1 (00:00 ÷ 23:56 / 0 ÷ 100%)

 

S2 (S1 ÷ 23:57 / 0 ÷ 100%)

 

S3 (22 ÷ 23:58 / 0 ÷ 100%)

 

S4 (S3 ÷ 23:59 / 0 ÷ 100%)

1.4.2 Saturdays

 - Setting time zones used on Saturdays.

 

S1 (00:00 ÷ 23:56 / 0 ÷ 100%)

 

S2 (S1 ÷ 23:57 / 0 ÷ 100%)

 

S3 (22 ÷ 23:58 / 0 ÷ 100%)

 

S4 (S3 ÷ 23:59 / 0 ÷ 100%)

1.4.3 Sundays 

- Setting time zones used on Sundays.

 

S1 (00:00 ÷ 23:56 / 0 ÷ 100%)

 

S2 (S1 ÷ 23:57 / 0 ÷ 100%)

 

S3 (22 ÷ 23:58 / 0 ÷ 100%)

 

S4 (S3 ÷ 23:59 / 0 ÷ 100%)

MENU

Figure 4. 

Organization of the menu.

Summary of Contents for ERO-32AP-0 V1.4

Page 1: ...REGULATOR PR DKO CI OBROTOWEJ ERO 32AP 0 V1 4 INSTRUCTION MANUAL WARRANTY CARD ELECTRONIC MOTOR SPEED COTROLLER ERO 32AP 0 V1 4 PL EN 2021 03 DARCO Sp z o o POLAND 39 200 D bica ul Metalowc w 43 tel...

Page 2: ...przed monta em i przegl dem urz dzenia nale y bez wzgl dnie od czy napi cie zasilaj ce 3 Nie montowa urz dzenia w miejscach gdzie mog wyst powa wysokie temperatury powy ej 50 C 4 Nie montowa urz dzen...

Page 3: ...analogowego lub cyfrowego K1 numer ekranu informacyjnego K2 wybrany czujnik zewn trzny brak czujnika czujnik analogowy czujnik cyfrowy PL MENU Rysunek 3 Organizacja ekran w informacyjnych Wyboru aktua...

Page 4: ...zostaje uruchomione z pr dko ci obrotow r wn V minimum 0 55 C 1 2 2 V minimum Ustawianie minimalnej pr dko ci obrotowej urz dzenia sterowanego 0 50 1 2 3 T maksimum Ustawianie temperatury przy kt rej...

Page 5: ...analogowym czujnikiem temperatury typu PT1000 W menu 1 1 pojawia si dodatkowy tryb pracy czujnikowy z mo liwo ci konfiguracji w podmenu 1 2 cyfrowy wej cie CZUJNIK wsp pracuje z dowolnym czujnikiem wy...

Page 6: ...dzenia sterowanego 1 Nie dokonano wyboru typu urz dzenia sterowanego menu Ustawienia Typ urz dzenia 2 Awaria wewn trzna sterownika 0000 0001 0000 Brak komunikacji z czujnikiem temperatury pokojowej ry...

Page 7: ...wymiany cz ci bez zgody producenta g zu ycia cz ci i materia w w normalnym trybie eksploatacyjnym 4 Konsumentowi przys uguje prawo wymiany zakupionego wyrobu na nowy je eli wyr b by dwukrotnie naprawi...

Page 8: ...ng the controller to electrical power should be made only by a quali fied electrician 2 Every time before mounting conservation etc unplug the device from electrical power 3 Avoid installing device in...

Page 9: ...r K1 information screen number K2 selected external sensor no sensor analogue sensor digital sensor K3 selected working mode sensor mode fixed mode zone mode fixed sensor mode zone sensor mode EN MENU...

Page 10: ...2 digital zone sensing the rotation speed of the controlled device is constant during the given period and depends on parameters set in sub menu 1 4 but only when the sensor is active otherwise the de...

Page 11: ...logue temperature sensor PT1000 type An additional working mode sensor appears in menu 1 1 with the option to configure it in sub menu 1 2 digital the SENSOR inputsupportsanysensorprovidedwitharelay t...

Page 12: ...cted 1 No type of the controlled device was selected in menu Settings Device type 2 Internal controller malfunction 0000 0001 0000 No communication with the room temperature sensor fig 1 item 5 1 Inte...

Page 13: ...damages caused by fires floods thunderstorms or other acts of God e damages caused by improper mounting f unauthorized dismantling remodeling fixing or part replacing g normal exploitation parts or ma...

Page 14: ...ler stamp piecz stamp data sprzeda y purchase date data i podpis klienta date signature Zapozna em am si i akceptuj warunki gwarancji I have read and accepted the warranty conditions Kr tki opis uszko...

Reviews: