USB3-FRM22 User’s Manual
22
(19) “YUV; RGB; RAW; USER” :
User setting or image input format selection
“No Skip” :
No Skip
“5’th Skip” :
When selected, the 5th byte is skipped. For example, if the input data is Bayer
with 10 bits, 8 bits each is stored in the 5th byte each of the remaining 1 bit
excluding RGB and 3 bytes and 1 byte. When Bayer is processed and displayed
on the screen, the 5th byte is not needed, so it is used when removing it.
“3’th Skip” :
When selected, the 3rd byte is skipped.
(20) “Get Res.” button
It shows the image resolution.
(21) “Read ID” button
It shows MIPI Iㅇ.
(22) “Full Scr.” :
It displays the screen in its original resolution size.
“Pause” :
Freeze the screen.
“Rolling” :
Update image data without using the GetFrame function.
“RB Swap” :
Red and blue signal values are interchanged.
3.2 Description of Clock Functions
(1) “PGM Clk” toggle
You can select the frequency range of the master clock supplied to the sensor.
The default is 26 MHz.
(2) “Set” button
MCLK(Master Clock) is set according to the next frequency. In the above case, it is set
to 26MHz. It can be set from 1039Hz to 68Mhz.
(3) “Set 6M” button
Set MCLK(Master Clock) to 6MHz.