USB3-FRM13_K Users Manual (Rev 1.1)
-
36
- http://www.daqsystem.com
(4)
“UART Send” button
Send the UART data.
(5)
“UART Get” button
Get the data from UART buffer.
(6)
“UART Clear” button
Clear the UART Receiver buffer.
5.5 Trigger Configure Functions for :Line Scan Camera
(1)
“Data(CC)Out” button
Make the CC (Camera Control) signal to be used from Low to High Active. It is from
CC1 to CC4. To make the signal of CC1 high active, write 1, CC2 write 2, CC3 write 4,
CC4 write 8. Write "F" to make them all high active.
(2)
“Line Scan Camera” toggle
If the box clicks, you can use a Line Scan Camera. Otherwise, you can use an Area Scan
Camera.
(3)
“Page Start” button
You can select Continuous, Page Trig, Z Phase modes.
Continuous --- The vertical resolution (Vsync) is repeatedly generated as many times as
the number set in # of Line.
Page Trig --- When the external trigger starts, vertical resolution (Vsync) is created once
as many as the number set in # of Line.
Z Phase --- When the Z-Phase (Z-Phase) of an external motor or encoder starts, vertical
resolution (Vsync) is generated once as much as the number set in # of Line.