background image

 

  

 

 

   

 

Ordercode: D3901 

Odin S-18A Line Array Sub 

How to Make a Data Cable 

A standard ETHERNET cable can be used to replace the data cable required to transmit data. 

 

Please follow the instructions below in order to create an extra net cable. 

 

Take a standard net cable (CAT-5/ 5E /6) and connect it to the RJ45 connector, as shown in the picture 
below (fig. 04). The wires should now be colored as follows: 
 

 

Fig. 04 

 
 

Maintenance 

The Odin S-18A Line Array Sub requires almost no maintenance. However, you should keep the unit 
clean. Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse 
in liquid. Do not use alcohol or solvents. 
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. 
Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 
 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps. 
 
01)

 

If the device does not operate properly, unplug the device. 

02)

 

Check the fuse, power from the wall, all cables, etc. 

03)

 

If all of the above appears to be O.K., plug the unit in again. 

04)

 

If you are unable to determine the cause of the problem, do not open the device, as this may 
damage the unit and the warranty will become void. 

05)

 

Return the device to your Dap Audio dealer. 

 
 

 

Summary of Contents for Odin S-18A

Page 1: ...Odin S 18A Line Array Sub V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3901 MANUAL ENGLISH...

Page 2: ...nnection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connectio...

Page 3: ...ke sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely...

Page 4: ...m could be created Make sure that there is sufficient room on all sides of the system for air circulation Make sure you do not use the wrong kind of cables or defective cables Make sure you use DI box...

Page 5: ...stion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02...

Page 6: ...136dB Cooling passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 Data IN LINK cascading connector External control 9 fixed presets 1 editable preset p...

Page 7: ...data output connector for cascading connections LED indicators SIG CLIP PROT POWER ACTIVE The indicators light up to indicate the status of the input signal 10 position preset selector Turn the selec...

Page 8: ...l link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the first speaker s power input...

Page 9: ...180 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at...

Page 10: ...use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying...

Page 11: ...table preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection Fan Overload Digital Limiter Compressor...

Page 12: ...2019 ODIN...

Reviews: