background image

 

  

  

10 

 

 

 

Ordercode: D6195 

MA-8120 Digital Zone Amplifier 

Maintenance 

The MA-8120 Digital Zone Amplifier requires almost no maintenance. However, you should keep the unit 
clean.  

Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in 

liquid. Do not use alcohol or solvents. 
Keep connections clean. Disconnect electric power, and then wipe the audio connections with a damp 

cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power. 

 
 

Troubleshooting 

MA-8120 Digital Zone Amplifier 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 

below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps. 

01)

 

If the device does not operate properly, unplug the device. 

02)

 

Check power from the wall, all cables, connections, etc. 

03)

 

If all of the above appears to be O.K., plug the unit in again. 

04)

 

If nothing happens after 30 seconds, unplug the device. 

05)

 

Return the device to your DAP Audio dealer. 

 

 

Product Specifications 

 
Outputs:  Power: 4 x 120W 

Zones: 4 

Tone control: High: 10kHz, Low 100Hz +/- 15dB 
100V/70V: Terminals 

Line output: Terminals 

 

Inputs: 

4 x Mic/Line: XLR & stereo jack connectors 

4 x Line: RCA & mono jack connectors 

 

Features:  Phantom power: +48V 

Tone control: Low 80 Hz, Mid: 2,5kHz, High 12kHz, +/-15dB 

Mic input: -60dB - -16dB / 20kOhm, balanced 
Line input: -20dB - +4dB / 20kOhm, balanced 

Remote input: 0B/600Ohm, balanced 
Frequency response: 20Hz–20kHz 

THD: < 0,1% 

 

General:  Input voltage: 230V AC, 50Hz 

Power consumption: 500W 

Power connection: IEC 
Fuse: T4AL/250V 

Dimensions:   482 x 345 x 89 mm (LxWxH) 

 

 

19 inch x 2HE 

Weight: 6 kg 

 

 
Design and product specifications are subject to change without prior notice. 

 

 

 

Website: 

www.Dap-audio.info

 

Email:

 [email protected]

 

 

 

 

Summary of Contents for MA-8120

Page 1: ...MA 8120 Digital Zone Amplifier V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D6195 MANUAL ENGLISH...

Page 2: ...fety Instructions 2 Operating Determinations 4 Return Procedure 4 Claims 4 Description of the device 5 Features 5 Overview 5 Frontside 6 Backside 7 Installation 7 Set Up and Operation 7 Connection Cab...

Page 3: ...ry box and packing Your shipment includes MA 8120 Digital Zone Amplifier User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be...

Page 4: ...er must be 50 100 higher than the loaded loudspeakers rated power In typical use please set the volume to 0dB position Make sure that the amplifier is turned down before turning the power on or off In...

Page 5: ...tion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a...

Page 6: ...an be controlled independently Each output has a 2 way tone control and a mute function The DAP MA 8120 is the ideal all in one solution for your multi zone installation which requires extended and co...

Page 7: ...he current output level Clip indicator This LED indicates overload If it is on turn the corresponding volume control to guarantee undistorted performance Protection indicator This LED indicates amplif...

Page 8: ...input tip sleeve XLR signal connectors IN Connect your signal source The channels 1 4 support balanced line and microphone input RCA line connectors IN Connect a line level unbalanced signal source T...

Page 9: ...reasing their lifespan and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unba...

Page 10: ...9 Ordercode D6195 MA 8120 Digital Zone Amplifier Block Diagram Fig 04...

Page 11: ...not operate properly unplug the device 02 Check power from the wall all cables connections etc 03 If all of the above appears to be O K plug the unit in again 04 If nothing happens after 30 seconds un...

Page 12: ...11 Ordercode D6195 MA 8120 Digital Zone Amplifier Dimensions...

Page 13: ...12 Ordercode D6195 MA 8120 Digital Zone Amplifier Notes...

Page 14: ...13 Ordercode D6195 MA 8120 Digital Zone Amplifier...

Page 15: ...14 Ordercode D6195 MA 8120 Digital Zone Amplifier...

Page 16: ...2017 DAP Audio...

Reviews: