background image

 

 

 

 

 

Ordercode: D4175 / D4176 / D4177 / D4178/D4179

         

6

 

HP-500 / HP-900 / HP-1500 / HP-2100/ HP-3000 

Description of the device 

 
The HP series is a family of powerful amplifiers which guarantee high output level. There are 5 available 
versions: HP-500, HP-900, HP-1500, HP-2100 and HP-3000. 
 

Features 

 
 

 

HP-500 

HP-900 

HP-1500 

HP-2100 

HP-3000 

Stereo 2Ohm: 

Not allowed 

Stereo 4Ohm: 

2 x 200W RMS 

2 x 450W RMS 

2 x 750W RMS 

2 x 1000W RMS  2 x 1400W RMS 

Stereo 8Ohm: 

2 x 150W RMS 

2 x 350W RMS 

2 x 500W RMS 

2 x 700W RMS 

2 x 1200W RMS 

Bridge 2Ohm: 

Not allowed 

Bridge 4Ohm: 

Not allowed 

Bridge 8Ohm: 

1 x 400W RMS 

1 x 900W RMS 

1 x 1500W RMS  1 x 2000W RMS  1 x 2800W RMS 

Frequency 
response: 

10Hz –20kHz, +0/-1dB 

THD: 

<0.5% 

S/N rate: 

>100dB A-weighted 

Crosstalk: 

>75dB 

Damping 
factor: 

>100 8Ohm 

Gain: 

32dB 

32dB 

34.5dB 

34.5dB 

36dB 

Input 
sensitivity: 

0,775V 

(+/-1dBv) 

0,85V 

(+/-1dBv) 

0,775V 

(+/-1dBv) 

0,85V 

(+/-1dBv) 

0,775V 

(+/-1dBv) 

Input 
impedance: 

20kOhm balanced, 10kOhm unbalanced 

Output Mode 

Stereo/ Parallel/ Bridge 

Amp 
technology: 

Class AB 

Class AB 

Class H 

Class H 

Class H 3-step 

Protection: 

Clip Limiter (Fixed), Short Circuit, Overheat, Overload, DC Voltage 

Cooling: 

Forced-air by axial fan 

Air flow: 

Front to back 

Input 
connectors: 

3-pin XLR IN 

Output 
connectors: 

Speakon OUT 

Power 
connector: 

IEC 

Input voltage: 

210-240V AC, 50/60Hz 

Power 
consumption 
(2x 4Ohm): 

600W 

1400W 

2210W 

2850W 

3800W 

Main Fuse: 

Auto Fuse, 3A, 

resettable 

Auto Fuse, 6A, 

resettable 

Auto Fuse, 

10A, resettable 

Auto Fuse, 

15A, resettable 

Auto Fuse, 

20A, resettable 

Fan: 

24V, 0.3A, 80x80x25mm 

Dimensions: 

483 x 310 x 88 mm (LxWxH) 

19” x 2HE 

Weight: 

8 kg 

10 kg 

12,7 kg 

14 kg 

17 kg 

 

 

Summary of Contents for HP-2100

Page 1: ...HP 500 HP 900 HP 1500 HP 2100 HP 3000 V1 Ordercode D4175 D4176 D4177 D4178 D4179 MANUAL ENGLISH Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands ...

Page 2: ...00 7 D4176 HP 900 7 D4177 HP 1500 7 D4178 HP 2100 8 D4179 HP 3000 8 Backside 9 D4175 HP 500 9 D4176 HP 900 9 D4177 HP 1500 9 D4178 HP 2100 10 D4179 HP 3000 10 Installation 11 Set Up and Operation 11 Mode Selection 11 Connection examples 12 Stereo Connection 12 Parallel Connection 13 Bridge Connection 14 Connection Cables 15 Maintenance 16 Troubleshooting 16 Product Specifications 17 Dimensions HP ...

Page 3: ...tion if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes DAP Audio HP 500 HP 900 HP 1500 HP 2100 HP 3000 IEC power cable 1 5 m User manual Safety Instru...

Page 4: ...iation exposure Do not switch the system on and off in short intervals as this would reduce the system s life Do not put your equipment next to TV radio etc because of interference or distortion If device is dropped or struck disconnect mains power supply immediately Have a qualified engineer inspect for safety before operating If the system has been exposed to drastic temperature fluctuation e g ...

Page 5: ...ntial to connect the yellow green conductor to earth The user is responsible for correct positioning and operating of the HP amplifier The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this device Repairs servicing and electric connection must be carried out by a qualified technician WARRANTY Till one year after date of purchase Operating Dete...

Page 6: ...ur address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the ...

Page 7: ...5 S N rate 100dB A weighted Crosstalk 75dB Damping factor 100 8Ohm Gain 32dB 32dB 34 5dB 34 5dB 36dB Input sensitivity 0 775V 1dBv 0 85V 1dBv 0 775V 1dBv 0 85V 1dBv 0 775V 1dBv Input impedance 20kOhm balanced 10kOhm unbalanced Output Mode Stereo Parallel Bridge Amp technology Class AB Class AB Class H Class H Class H 3 step Protection Clip Limiter Fixed Short Circuit Overheat Overload DC Voltage C...

Page 8: ...Ordercode D4175 D4176 D4177 D4178 D4179 7 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Frontside D4175 HP 500 Fig 01 D4176 HP 900 Fig 02 D4177 HP 1500 Fig 03 ...

Page 9: ... In this case decrease your source signal level until the LED turns off Please keep in mind that the amplifier itself cannot correct any distortion SIGNAL When the LED lights in green it means that the HP is operating within its safety limits PROTECT The LED will light in orange when the amplifier is in protection mode Switch off the device and find out what the problem is The amplifier is protect...

Page 10: ...Ordercode D4175 D4176 D4177 D4178 D4179 9 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Backside D4175 HP 500 Fig 06 D4176 HP 900 Fig 07 D4177 HP 1500 Fig 08 ...

Page 11: ...connector OUT Connect the device to speakers Mode switch With this switch you can choose between the 3 operation modes bridge parallel and stereo STEREO 2 inputs channel 1 and 2 and 2 outputs are used PARALLEL 1 input channel 1 and 2 outputs are used BRIDGE 1 input channel 1 and 1 output are used only use at 8Ohm Bridge Speakon connector OUT Connect the device to speakers in Bridge mode CH 1 3 pin...

Page 12: ...or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging the unit in always make sure that the power supply matches the product specification voltage Do not attempt to operate a 120V specification product on 240V power or vice versa Install this device on a flat surface not bending or curved Do not supply power before all components of the syst...

Page 13: ...Ordercode D4175 D4176 D4177 D4178 D4179 12 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Connection examples Stereo Connection Fig 12 ...

Page 14: ...Ordercode D4175 D4176 D4177 D4178 D4179 13 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Parallel Connection Fig 13 ...

Page 15: ...Ordercode D4175 D4176 D4177 D4178 D4179 14 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Bridge Connection Fig 14 ...

Page 16: ... advantage of increasing their lifespan and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most professional audio devices Follow the configuration examples below fo...

Page 17: ...loth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting HP 500 HP 900 HP 1500 HP 2100 HP 3000 This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found If the unit operates properly do not carry out following steps 01 If the device does not operate ...

Page 18: ... 1dBv 0 85V 1dBv 0 775V 1dBv Input impedance 20kOhm balanced 10kOhm unbalanced Output Mode Stereo Parallel Bridge Amp technology Class AB Class AB Class H Class H Class H 3 step Protection Clip Limiter Fixed Short Circuit Overheat Overload DC Voltage Cooling Forced air by axial fan Air flow Front to back Input connectors 3 pin XLR IN Output connectors Speakon OUT Power connector IEC Input voltage ...

Page 19: ...Ordercode D4175 D4176 D4177 D4178 D4179 18 HP 500 HP 900 HP 1500 HP 2100 HP 3000 Dimensions HP 500 HP 900 HP 1500 HP 2100 HP 3000 ...

Page 20: ... 2017 DAP Audio ...

Reviews: