background image

 

WARNING 

 
 
 
 
 
 

 

 

SAFETY INSTRUCTIONS 

Every person involved with the installation, operation and maintenance of this system has to: 

-

 

be qualified 

-

 

follow  the instructions of this manual 

 
 
 
 
 
 
 
 
Before you initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the system. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes written in this manual. 
 
Please consider that damages caused by manual modifications to the system are not subject to 
warranty. 
 
This system contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT:

 

The manufacturer will not accept liability for any resulting damages caused by the non-
observance of this manual or any unauthorized modification to the system. 

 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this system to a dimmerpack. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Do not open the device and do not modify the device. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full 
output. 

 

Do not plug Mics into the console (or stagebox) while Phantom Power is on. Also mute the monitor 
/ Pa system when turning Phantom Power on or off. Allow the system to adjust for a couple of 
seconds, before setting the input gains. 

 

Only use system indoor, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when system is not used. Only handle the power-cord 
by the plug. Never pull out the plug by tugging the power-cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

CAUTION! 

 

Keep this system away from rain and moisture! 

 

CAUTION! Be careful with your operations. 

With a dangerous voltage you can suffer 

a dangerous electric shock when touching the wires!

 

 

Summary of Contents for DS-CM-6

Page 1: ...DS CM 6 ORDERCODE D2181...

Page 2: ...Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our cu...

Page 3: ...Guide Warning Unpacking Instructions Return Procedure Safety instructions Operating Determinations Description Overview Frontside Backside Installation Functions Set Up and Operation Maintenance Repl...

Page 4: ...product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside th...

Page 5: ...Do not insert objects into air vents Do not connect this system to a dimmerpack Do not switch the system on and off in short intervals as this would reduce the system s life Do not open the device an...

Page 6: ...rising condensation water might damage your system Leave the system switched off until it has reached room temperature If your Dap Audio device fails to work properly discontinue use immediately Pack...

Page 7: ...Balanced Input 21 Master Balance 5 Low 22 PFL Master Switch 6 DJ Mic Level 23 Power ON LED 7 Mic 2 Level 24 Power Switch 8 Mic channel PFL Switch 25 Output Signal VU meter 9 Channel Input Selector Pho...

Page 8: ...ion the input level of channel 1 4 is attenuated by 12dB Making it easy for you to make an an anouncement using the DJ microphone B On With the switch in this position the talkover function is deactiv...

Page 9: ...sign more than one channel simultaneously to the PFL bus 11 Gain Use this control to match the connected devices optimally to your DS CM 6 The fader set to 0dB Adjust the gain with a loud input signal...

Page 10: ...on 30 CF Monitor Use this control to make a headphone mix between your PFL and your master signal 31 Headphones Volume This control allows you to adjust the headphones volume 32 Headphone You can conn...

Page 11: ...e specification T250mA 41 Master RCA Unbalanced Out Use these outputs to connect an amplifier with balanced inputs 42 Master RCA Unbalanced Out Use these outputs to connect an amplifier with unbalance...

Page 12: ...e versa Connection Cables Take care of your cables always holding them by the connectors and avoiding knots and twists when coiling them This gives the advantage of increasing their life and reliabili...

Page 13: ...supplying electric power Replacing a Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoev...

Page 14: ...Troubleshooting DAP Audio CD Player DS CM 6 This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once...

Page 15: ...e 3mV 47k phono 150mV 100k aux 150mV 100k Output level master 775mV 600 Record 400mV 600 Phones 775mV 600 Frequency response 20Hz 20kHz THD 0 1 Stereo separation 45dB Signal noise ratio mic 75dB phono...

Page 16: ...2009 DapAudio...

Reviews: