background image

 

Ordercode: D4212 / D4213 

DM-1000 / DM-2000 

Operating Determinations 

This system is not designed for permanent operation. Consistent operation breaks will ensure that the 

system will serve you for a long time without defects. 

 

If this system is operated in any other way than the one described in this manual, the product may suffer 

damages and the warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 

 

You endanger your own safety and the safety of others ! 

 

Improper installation can cause serious damage to people and property ! 

 

 

 

 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 

without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 

Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 

return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 

customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 

product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 

 

Note: If you are given an RMA number, please include the following information on a piece of paper 

inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-

comings and/or visible defects, or perform this check after our announcement that the goods are at their 

disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. 

It is the customer's responsibility to notify and submit claims with the shipper in the event that a device is 

damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 

of the delivery.  

Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 

a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 

otherwise agreed in writing. 

Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 

invoice. After this period complaints will not be handled anymore. 

Complaints will only then be considered if the client has so far complied with all parts of the agreement, 

regardless of the agreement of which the obligation is resulting. 

 

 

 

  

 

 

   

 

Summary of Contents for DM-1000

Page 1: ...DM 1000 DM 2000 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D4212 D4213 MANUAL ENGLISH...

Page 2: ...tions 4 Return Procedure 4 Claims 4 Description of the device 5 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Stereo Connection 8 Parallel Connection 9 Bridge Connection 10 Connection C...

Page 3: ...packing Your shipment includes DM 1000 DM 2000 Schuko power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be q...

Page 4: ...cking material and return it to your Dap Audio dealer for service In system setup the amplifier s output power must be 50 100 higher than the loaded loudspeakers rated power In typical use please set...

Page 5: ...repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece...

Page 6: ...y PFC Switching Power Amp CLASS D Protections Short circuit open circuit thermal ultrasonic and RF protection Input connectors RCA and XLR Combo Output connectors 2x Speakon binding posts Dimensions 4...

Page 7: ...s in protection mode Switch off the device and find out what the problem is The amplifier is protected against overheating overload short circuit etc Decrease the source signal level and or improve ai...

Page 8: ...or hot Pin 1 3 Sleeve shield ground Mode switch Flick the switch to select your desired operation mode parallel bridge or stereo 3 pin XLR Link connector OUT Connect the DM to another amplifier RCA c...

Page 9: ...ing or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging the unit in always make sure that the power supply matches the product specification...

Page 10: ...Ordercode D4212 D4213 DM 1000 DM 2000 Parallel Connection Fig 04 9...

Page 11: ...Ordercode D4212 D4213 DM 1000 DM 2000 Bridge Connection Fig 05 10...

Page 12: ...onnection Maintenance The DM 1000 DM 2000 requires almost no maintenance However you should keep the unit clean Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immer...

Page 13: ...lew rate 40 V S Input CMRR 60 dB Crosstalk 20 20 000 Hz 70 dB Signal to Noise Ratio 96 dB A weighted Power circuitry PFC Switching Power Amp CLASS D Protections Short circuit open circuit thermal ultr...

Page 14: ...Ordercode D4212 D4213 DM 1000 DM 2000 Dimensions 13...

Page 15: ...Ordercode D4212 D4213 DM 1000 DM 2000 14...