background image

 

Backpanel 

 

 

Fig. 3 

 

17. 

AC Inlet with integrated fuse holder 

This connector is meant for the connection of the supplied main cord. Connect one end of the power 
cord to the connector, the other end to the mains, then turn on the 

power (16)

 switch to operate the 

unit.  

Make sure that the supply voltage matches the operation voltage before connecting the unit to mains. 

Replace the fuse only with a fuse of the same specification (230V:T3,15A, 115V:T6,3A).

 

 
18. AC-selector 

Before connecting your MA-460 to the mains, make sure the AC-selector is set to the proper voltage used 
in your country. If you’re not sure, consult a skilled technician.

 

 

19

. Zone line out terminal 

These terminals allow you to connect an external amplifier to a zone in case the internal amplifier can’t 
provide sufficient power. The terminals allow you to connect a balanced or unbalanced amplifier input.  
 

20

. Zone com speaker terminal 

Connect these terminal with the – terminal of your zone speaker(s).

 

 

21. Zone 8Ω impedance speaker terminals 

Connect this terminal to the + terminal of a 8

Ω 

speakerload.  

In case of using several speakers, make sure that the total speaker load is the same as the impedance of 
the corresponding terminal. The total power rating of the low impedance  speakers connected to this 
terminal summed, should be at least 60W.

 

 

22. Zone 70V output terminal 

Each zone has its own output terminal. Connect this terminal to the + terminal of your 70V high 
impedance speaker load. In case of using several speakers make sure all speakers are wired in parallel. 

The total power rating of the high impedance speakers connected to this terminal summed, should never 
exceed 60W.

 

 

23

. Monitor line out terminal 

These terminals allow you to connect an external monitor amplifier. The output level is controlled by the 

monitor level (15) 

control. 

 

24

. Monitor 8Ω 1W out terminal 

These terminals allow you to connect an external 1W 8Ω monitor speaker. The output level is controlled 
by the 

monitor level (15) 

control. 

 

 

 

Summary of Contents for D6148

Page 1: ...MA 460 ORDERCODE D6148 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...erminations 4 Return Procedure 5 Description of the device 6 Frontpanel 6 Backpanel 8 Operation 10 Installation 10 Set Up and Operation 10 Connecting Inputs 10 Connecting Outputs 10 Low impedance outp...

Page 4: ...er and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this ma...

Page 5: ...cur it is necessary to reduce the input signal level by using the INPUT control To emphasize a frequency range you don t necessarily have to move its respective control upward try lowering surrounding...

Page 6: ...method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of th...

Page 7: ...eries Features 4 individual 60W outputs 5 Inputs with matrix functionality Bass Treble control on each channel Front line input 3 5mm Jack Pre amp zone outputs Telephone paging with volume zone contro...

Page 8: ...nel mute button Pushing this button allows you to mute the corresponding channel If a channel is muted the corresponding mute 4 LED will light up 13 Monitor VU meter Indicates the signal level at the...

Page 9: ...eaker terminal Connect these terminal with the terminal of your zone speaker s 21 Zone 8 impedance speaker terminals Connect this terminal to the terminal of a 8 speakerload In case of using several s...

Page 10: ...the impedance of the corresponding terminal The total power rating of the low impedance speakers connected to this terminal summed should be at least 60W 34 Zone 25V high impedance terminals Each zon...

Page 11: ...t on 230V power or vice versa Before powering up the first time make sure the AC selector switch is set to the proper voltage Damage caused by connecting the amplifier to improper AC voltage is not co...

Page 12: ...This to avoid overloading the amplifier The total speaker power should be at least the power of the amplifier to avoid damage to the speakers High impedance outputs If using either the 25V 70V or 100...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...t operate properly unplug the device 2 Check power from the wall all cables connections etc 3 If all of the above appears to be O K plug the unit in again 4 If nothing happens after 30 seconds unplug...

Page 15: ...le gain RCA Input 5 Line with variable gain RCA Indication LEDs VU bar with clip indication each zone Tone control Bass 100 Hz treble 10 KHz 12dB Priority Input 1 terminal strip N O contact Monitor ou...

Page 16: ...2013 DapAudio...