25. 

Priority remote terminal 

Use this terminal for connecting a remote switch or relay contact. If these two contacts are shorted, all 
inputs except 

combo input 1 (30)

 will be muted when 

combo input 1 (30)

 detects a sound.

 

 

26. Telephone paging

 terminal 

Use this terminal for connecting a telephone system equipped with a paging output. 

 

27. Telephone paging level control 

Use to adjust the input volume level for the 

telephone paging (26)

 terminal.

 

 

28. Telephone paging assign dipswitch 

Use to assign the telephone paging input to one or more zones. 
 

29. Input 1 Impedance/level switch 

This switch allows you to set up combo input 1 for line level, microphone level with phantom power or 
microphone level without phantom power. 
 

30. Combo input 1 

Combo input for channel 1. Accepts balanced or unbalanced inputs.

 

 

31. Input 1 gain control 

Use to adjust the input gain for 

input 1 (30)

.

 

 
32. 

GND Screw  

This screw offers a separate ground connection. Can be useful in case of grounding problems.

 

 

33. Zone 4Ω impedance speaker terminals 

Connect this terminal to the + terminal of a 4

Ω 

speakerload.  

In case of using several speakers, make sure that the total speaker load is the same as the impedance of 
the corresponding terminal. The total power rating of the low impedance  speakers connected to this 
terminal summed, should be at least 60W.

 

 

34. Zone 25V high impedance terminals 

Each zone has its own output terminal. Connect this terminal to the + terminal of your 25V high 
impedance speaker load. In case of using several speakers make sure all speakers are wired in parallel. 

The total power rating of the high impedance speakers connected to this terminal summed, should never 
exceed 60W.

 

 
35. Zone 100V high impedance terminals 

Each zone has its own output terminal. Connect this terminal to the + terminal of your 100V high 
impedance speaker load. In case of using several speakers make sure all speakers are wired in parallel. 

The total power rating of the high impedance speakers connected to this terminal summed, should never 
exceed 60W.

 

 
36. Input 5 gain control 

Use to adjust the input gain for 

input 5 (37)

.

 

 
37.

 

Input 5 

RCA stereo input for connecting a line level device such as an I-pod, CD player etc. 
 

38.

 

Input 4 

RCA stereo input for connecting a line level device such as an I-pod, CD player etc. 
 

39. Input 4 gain control 

Use to adjust the input gain for 

input 4 (38)

.

 

 

40. Input 3 Impedance/level switch 

This switch allows you to set up combo input 3 for line level, microphone level with phantom power or 
microphone level without phantom power. 
 

Summary of Contents for D6148

Page 1: ...MA 460 ORDERCODE D6148 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands...

Page 2: ...P Audio for more excellent audio products We design and manufacture professional audio equipment for the entertainment industry New products are being launched regularly We work hard to keep you our c...

Page 3: ...erminations 4 Return Procedure 5 Description of the device 6 Frontpanel 6 Backpanel 8 Operation 10 Installation 10 Set Up and Operation 10 Connecting Inputs 10 Connecting Outputs 10 Low impedance outp...

Page 4: ...er and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this ma...

Page 5: ...cur it is necessary to reduce the input signal level by using the INPUT control To emphasize a frequency range you don t necessarily have to move its respective control upward try lowering surrounding...

Page 6: ...method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of th...

Page 7: ...eries Features 4 individual 60W outputs 5 Inputs with matrix functionality Bass Treble control on each channel Front line input 3 5mm Jack Pre amp zone outputs Telephone paging with volume zone contro...

Page 8: ...nel mute button Pushing this button allows you to mute the corresponding channel If a channel is muted the corresponding mute 4 LED will light up 13 Monitor VU meter Indicates the signal level at the...

Page 9: ...eaker terminal Connect these terminal with the terminal of your zone speaker s 21 Zone 8 impedance speaker terminals Connect this terminal to the terminal of a 8 speakerload In case of using several s...

Page 10: ...the impedance of the corresponding terminal The total power rating of the low impedance speakers connected to this terminal summed should be at least 60W 34 Zone 25V high impedance terminals Each zon...

Page 11: ...t on 230V power or vice versa Before powering up the first time make sure the AC selector switch is set to the proper voltage Damage caused by connecting the amplifier to improper AC voltage is not co...

Page 12: ...This to avoid overloading the amplifier The total speaker power should be at least the power of the amplifier to avoid damage to the speakers High impedance outputs If using either the 25V 70V or 100...

Page 13: ...em This gives the advantage of increasing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using un...

Page 14: ...t operate properly unplug the device 2 Check power from the wall all cables connections etc 3 If all of the above appears to be O K plug the unit in again 4 If nothing happens after 30 seconds unplug...

Page 15: ...le gain RCA Input 5 Line with variable gain RCA Indication LEDs VU bar with clip indication each zone Tone control Bass 100 Hz treble 10 KHz 12dB Priority Input 1 terminal strip N O contact Monitor ou...

Page 16: ...2013 DapAudio...