background image

 

  

 

 

   

 

Ordercode: D3902 

Odin S-218A Ultra Sub 

IMPORTANT! 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the system. 
 

 

Always disconnect power from the mains, when system is not used. Only handle the power cord by the 
plug. Never pull out the plug by tugging the power cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the same 
electrical circuit to ensure the same phase! 

 

Avoid installing your equipment very near radio or TV sets, mobile phones, etc., as these can cause RF 
(radio frequency) interference. 

 

Before changing your grounds around, always turn your amplifiers down. 

 

Before connecting or disconnecting the power cord, make sure that the ON/OFF switch is in the OFF 
position. 

 

Before switching on or off, make sure that the sound system’s amplifiers are off or turned down: this will 
avoid signal peaks, which are annoying and sometimes dangerous (particularly for speaker enclosures). 

 

Do not connect this device to a dimmer pack. 

 

Do not drive the inputs with a signal level higher than required to drive the equipment to full output. 

 

Do not insert objects into air vents. 

 

Do not open this device. Risk: hazardous radiation exposure. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT control. 

 

For replacement use fuses of same type and rating only. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified engineer 
inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the system 
switched off until it has reached room temperature. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power cord 
from time to time. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure that there is sufficient room on all sides of the system for air circulation. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input mode 
switch. 

 

Prevent distortion! Make sure that all components connected to the Odin have sufficient power ratings. 
Otherwise distortion will be generated because the components are operated at their limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

The best way (even if not always feasible) to avoid ground loops is to connect the electric ground of all 
the equipment to a single central point (“star” system). In this case, the central point can be the mixer. 

 

To avoid or solve hum and buzzing troubles, try different combinations of lifting grounds on units that are 
supplied with ground lift switches or make sure all chassis are connected to earth ground, either through 
the A.C. power cord ground or by the front panel rack mount screws. 

 

To emphasize a frequency range, you do not necessarily have to move its respective slider upwards; 
instead, try lowering surrounding frequency ranges. This way, you avoid causing the next piece of 
equipment in your sound path to overdrive. You also preserve valuable dynamic reserve (“headroom”). 

 

When connecting the other parts of your sound system, watch out for the so-called “ground loops”. 

 

WARRANTY: Till one year after date of purchase.

 

 

 

Summary of Contents for D3902

Page 1: ...Odin S 218A Ultra Sub V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3902 MANUAL ENGLISH ...

Page 2: ...nection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connection Cables 8 How to Make a Data Cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Page 3: ...hipment includes Odin S 218A Ultra Sub Power cable NOT included Network cable NOT included User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your deale...

Page 4: ...ched off until it has reached room temperature Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that the signals into the mixer are balanced otherwise hum could be created Make sure that there is sufficient room on all sides of the system for air...

Page 5: ...tion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visibl...

Page 6: ... Directivity Omnidirectional Cooling Passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 data IN LINK cascading connector External control 9 fixed presets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protection Thermal Convection fan Overload Digital limiter Co...

Page 7: ...el input connector RJ45 data connector IN RJ45 data input connector RJ45 data connector LINK RJ45 data link connector for cascading connections 10 position preset selector Turn the selector to choose one of the 10 equalizer presets See page 8 for more information PowerCON 100 240V AC power connector IN Blue Connect to an appropriate power supply PowerCON 100 240V AC power connector LINK Gray This ...

Page 8: ... the audio signal input 03 on your speaker 02 Using an XLR cable connect the audio signal link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the speaker s power input 07 to the power supply Please note that it is allowed to connect only 1 speaker per phase 16A 04 In order to enable d...

Page 9: ...80 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at a level of 0 dB 5 Entertainment Phase 180 Inverted Preset for entertainment use DJ Playback Phase 180 Inverted crosspoint at 125 Hz set at a level of 0 dB 6 Cardioid Use the in phase preset 0 on the fr...

Page 10: ... alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates...

Page 11: ...esets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection fan Overload Digital limiter Compressor Mains connector Neutrik PowerCON connector IN OUT Power supply 100 240V AC 50Hz 60Hz Power consumption 4000W Enclosure construction 18 mm Birch Plywood resistant black paint 1 5T metal gri...

Page 12: ... 2019 ODIN ...

Reviews: