background image

 

  

 

 

   

 

Ordercode: D3902 

Odin S-218A Ultra Sub 

How to Make a Data Cable 

A standard ETHERNET cable can be used to replace the data cable required to transmit data. 

 

Please follow the instructions below in order to create an extra net cable. 

 

Take a standard net cable (CAT-5/ 5E /6) and connect it to the RJ45 connector, as shown in the picture 
below (Fig. 04). The wires should now be colored as follows: 
 

 

Fig. 04 

 
 

Maintenance 

The Odin S-218A Ultra Sub requires almost no maintenance. However, you should keep the unit clean. 
Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in 
liquid. Do not use alcohol or solvents. 
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. 
Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 
 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out following 
steps. 
 
01)

 

If the device does not operate properly, unplug the device. 

02)

 

Check the fuses, power from the wall, all cables, etc. 

03)

 

If all of the above appears to be O.K., plug the unit in again. 

04)

 

If you are unable to determine the cause of the problem, do not open the device, as this may 
damage the unit and the warranty will become void. 

05)

 

Return the device to your Dap Audio dealer. 

 
 

 

Summary of Contents for D3902

Page 1: ...Odin S 218A Ultra Sub V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3902 MANUAL ENGLISH ...

Page 2: ...nection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connection Cables 8 How to Make a Data Cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Page 3: ...hipment includes Odin S 218A Ultra Sub Power cable NOT included Network cable NOT included User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your deale...

Page 4: ...ched off until it has reached room temperature Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that the signals into the mixer are balanced otherwise hum could be created Make sure that there is sufficient room on all sides of the system for air...

Page 5: ...tion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visibl...

Page 6: ... Directivity Omnidirectional Cooling Passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 data IN LINK cascading connector External control 9 fixed presets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protection Thermal Convection fan Overload Digital limiter Co...

Page 7: ...el input connector RJ45 data connector IN RJ45 data input connector RJ45 data connector LINK RJ45 data link connector for cascading connections 10 position preset selector Turn the selector to choose one of the 10 equalizer presets See page 8 for more information PowerCON 100 240V AC power connector IN Blue Connect to an appropriate power supply PowerCON 100 240V AC power connector LINK Gray This ...

Page 8: ... the audio signal input 03 on your speaker 02 Using an XLR cable connect the audio signal link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the speaker s power input 07 to the power supply Please note that it is allowed to connect only 1 speaker per phase 16A 04 In order to enable d...

Page 9: ...80 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at a level of 0 dB 5 Entertainment Phase 180 Inverted Preset for entertainment use DJ Playback Phase 180 Inverted crosspoint at 125 Hz set at a level of 0 dB 6 Cardioid Use the in phase preset 0 on the fr...

Page 10: ... alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates...

Page 11: ...esets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection fan Overload Digital limiter Compressor Mains connector Neutrik PowerCON connector IN OUT Power supply 100 240V AC 50Hz 60Hz Power consumption 4000W Enclosure construction 18 mm Birch Plywood resistant black paint 1 5T metal gri...

Page 12: ... 2019 ODIN ...