background image

 

  

 

 

   

 

Ordercode: D3901 

Odin S-18A Line Array Sub 

Backside 

 

 

Fig. 02 

 

Rigging pin 

 

3-pin XLR audio connector LINK 
Connected in parallel with the XLR input (03). Use the connector to send an audio signal to 
another active speaker. 

 

3-pin XLR audio connector IN 
Balanced XLR line level input connector. 

 

RJ45 data connector IN 
RJ45 data input connector. 

 

RJ45 data connector LINK 
RJ45 data output connector for cascading connections. 

 

LED indicators SIG/CLIP/PROT/POWER/ACTIVE 
The indicators light up to indicate the status of the input signal. 

 

10-position preset selector 
Turn the selector to choose one of the 10 equalizer presets. See page 8 for more information. 

 

PowerCON 100-240V AC power connector IN (Blue) 
Connect to an appropriate power supply. 

 

Fuse T6,3AL/250V 

 

Power switch ON/OFF 

 

PowerCON 100-240V AC power connector LINK (Gray) 
This output is connected in parallel with the PowerCON input (08) and can be used for powering 
another active speaker. 

 

 

Summary of Contents for D3901

Page 1: ...Odin S 18A Line Array Sub V3 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3901 MANUAL ENGLISH ...

Page 2: ...onnection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Backside 6 Installation 7 Connection Example 7 Set Up and Operation 8 Preset Selector 8 Presets 8 Connection Cables 8 How to Make a Data Cable 9 Maintenance 9 Troubleshooting 9 Product Specifications 10 ...

Page 3: ...ake sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the system are not subject to warrant...

Page 4: ...um could be created Make sure that there is sufficient room on all sides of the system for air circulation Make sure you do not use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with partic...

Page 5: ...estion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visi...

Page 6: ... 136dB Cooling passive cooling forced cooling inside Audio connector 3 pin XLR connector IN OUT Data connector RJ45 Data IN LINK cascading connector External control 9 fixed presets 1 editable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic Protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connec...

Page 7: ...5 data output connector for cascading connections LED indicators SIG CLIP PROT POWER ACTIVE The indicators light up to indicate the status of the input signal 10 position preset selector Turn the selector to choose one of the 10 equalizer presets See page 8 for more information PowerCON 100 240V AC power connector IN Blue Connect to an appropriate power supply Fuse T6 3AL 250V Power switch ON OFF ...

Page 8: ...al link 02 on your first speaker to the audio signal input 03 on your second speaker Repeat this step to connect multiple speakers 03 Using a PowerCON power cord connect the first speaker s power input 08 to the power supply 04 Using PowerCON power cords connect the first active speaker s power link 11 to the second speaker s power input 08 Repeat this step to connect the third and fourth speaker ...

Page 9: ... 180 Inverted Preset for live use Bands Performances Phase 180 Inverted crosspoint at 105 Hz set at a level of 0 dB 4 Entertainment Preset for entertainment use DJ Playback crosspoint at 125 Hz set at a level of 0 dB 5 Entertainment Phase 180 Inverted Preset for entertainment use DJ Playback Phase 180 Inverted crosspoint at 125 Hz set at a level of 0 dB 6 Cardioid Use the in phase preset 0 on the ...

Page 10: ...t use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit ope...

Page 11: ...itable preset power switch with LED indicators for CLIP SIG PROT DSP processor 32bit 24bit 48kHz audio conversion AD DA Electronic protections Thermal Convection Fan Overload Digital Limiter Compressor Mains connector Neutrik PowerCON connector IN OUT Power supply 100 240V AC 50Hz 60Hz Power consumption 2000W Enclosure construction 18 mm birch plywood resistant black paint 1 5T metal grill with fo...

Page 12: ... 2019 ODIN ...

Reviews: