IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never remove warning or informative labels from the unit. 

 

Never leave any cables lying around. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 

the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Make sure that the power cord is never crimped or damaged. Check the system and the power 

cord from time to time. 

 

If system is dropped or struck, disconnect the power supply immediately. Have a qualified engineer 

inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your system. Leave the 

system switched off until it has reached room temperature. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 

(preferably in the original packing material), and return it to your Dap Audio dealer for service. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

Operating Determinations  

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 

device will serve you for a long time without defects. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 

suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 

Connection with the mains 

Connect the device to the mains with the power-plug. 

Always pay attention, that the right color cable is connected to the right place. 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

PHASE

 

BLUE 

BLACK 

SILVER 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

Improper installation can cause serious damage to people and property! 

 

 

  

 

 

   

 

Summary of Contents for D1333

Page 1: ...DM 25 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D1333 MANUAL ENGLISH ...

Page 2: ...h the mains 3 Return Procedure 4 Claims 4 Description of the device 5 Overview Fout Bladwijzer niet gedefinieerd Installation 5 Set Up and Operation 6 Setup Example 6 Frequency 6 Connection Cables 7 Compensation of Interference With Balanced Connections 8 Maintenance 8 Troubleshooting 8 Product Specifications 9 1 ...

Page 3: ...acking Your shipment includes DAP Audio DM 25 DM 25 case User manual Safety Instructions Every person involved with the installation operation and maintenance of this system has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To main...

Page 4: ...our system Leave the system switched off until it has reached room temperature If your Dap Audio device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Dap Audio dealer for service Repairs servicing and electric connection must be carried out by a qualified technician WARRANTY Till one year after date of pu...

Page 5: ... 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchan...

Page 6: ...1000Hz Impedance 500 Ω Connections 1 x 3 pin XLR OUT Accessories Thread adapter 5 8 4 8 3 8 integrated stand storage case Dimensions case 300 x 120 x 75 mm LxWxH Dimensions microphone 105 x 40 x 85 mm LxWxH Weight 0 2 kg Optional accessories D8930 Microphone drum clamp D8931 Microphone drum clamp Overview Fig 01 3 pin XLR OUT Body Head Installation Remove all packing materials from the DM 25 Check...

Page 7: ...amp or recording device to the minimum before connecting the microphone Make sure that the phantom power is off 02 Once the DM 25 is plugged in move the channel fader gradually to the 0dB position Adjust the input gain using your channel peak LED or the VU meter Setup Example Fig 02 Frequency Fig 03 6 ...

Page 8: ... reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced Headphones Insert For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most professional audio devices Follow the configuration examples below for your particular connect...

Page 9: ...sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting DAP Audio DM 25 This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps 01 If the device does not operate properly unplug the device 02 ...

Page 10: ...equency response 50 16000Hz Polar pattern Super Cardioid Sensitivity 1000Hz 2 2 mV Pa 1 Pa 94dB SPL Maximum SPL 134dB THD 1 1000Hz Impedance 500 Ω Connections 1 x 3 pin XLR OUT Accessories Thread adapter 5 8 4 8 3 8 integrated stand storage case Max ambient temperature ta 40 C Max housing temperature tB 80 C Design and product specifications are subject to change without prior notice Website www D...