Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Don't put your equipment next to TV, radio, etc., because of interference or distortion. 

 

For replacement use fuses of same type and rating only. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

If you connect other parts of the system, be careful of ground loops. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material) and return it to your Dap Audio dealer for service. 

 

In system setup, the amplifier's output power must be 50%-100% more than the loaded loudspeakers 
rated power. 

 

In typical use, please set the volume at 0dB position. 

 

Make sure that the amplifier is turned down, before turning the power on or off. So you can avoid 
supersonic frequencies, which could damage your speakers. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power-cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure you don’t use the wrong kind of cables or defective cables. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear 

 

Never let the power-cord come into contact with other cables! Handle the power-cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Please read this manual carefully and keep it for future reference. Remember that the amplifier has 
a better value on the market, if you save the carton and all packing materials. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Prevent distortion! Make sure that all components connected to the device have sufficient power 
ratings. Otherwise distortion will be generated because the components are operated at their limits. 

 

Prevent distortion! Make sure that all components connected to the CX Amplifier have sufficient 
power ratings. Otherwise distortion will be generated because the components are operated at their 
limits. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

Sometimes, when you want to send one signal to more than one amplifier, you should use a signal 
distributor. 

 

The best way to avoid ground loops is connecting the electrical system ground to one central point 
("star" system). In this case the mixer can act as a central point. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

WARRANTY: Till one year after date of purchase. 

 
 

Disposing of this product should not be placed in municipal waste and should be 
separate collection. 

 

 

Summary of Contents for CX-1500

Page 1: ...Productcode D4162 D4163 D4164 D4165 D4166 Productname CX 500 CX 900 CX 1500 CX 2100 CX 3000 CX Series Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands MANUAL ENGLISH...

Page 2: ...e mains 4 Return Procedure 4 Claims 4 Functions Features 5 Operation 5 Installation 5 Set Up and Operation 5 Mode Selection 5 Main operation Key Functions 6 Front Panel 6 Rear Panel 6 Speakon output c...

Page 3: ...fer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification...

Page 4: ...kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle th...

Page 5: ...er UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your addres...

Page 6: ...pment into a 19 rack Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operatio...

Page 7: ...overheat overload short circuit DC Limit LED Any illumination of the clip LED indicates distortion In this case check the signal of your source and turn down the input gain control Please keep in min...

Page 8: ...h This switch is used to select the operating mode of the power amplifier Stereo 2 inputs channel 1 and 2 and 2 outputs are used Parallel 1 input channel 1 and 2 outputs are used Bridge 1 input channe...

Page 9: ...8 CX Series CX 500 900 1500 2100 3000 Parallel connection Bridge connection...

Page 10: ...ng their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Ba...

Page 11: ...ohms Construction Protection Protection against short circuits no load on off muting RF interference Ventilation Flow through ventilation from front to back Cooling Internal heat sinks with forced air...

Page 12: ...2013 DAP Audio...

Reviews: