Do not insert objects into air vents. 

 

Do not switch the system on and off in short intervals, as this would reduce the system’s life. 

 

Do not open the device and do not modify the device. 

 

Do not drive the inputs with a signal level bigger, than required to drive the equipment to full output. 

 

Do not plug mics into the console (or stagebox) while phantom power is on. Also mute the monitor / 
Pa system when turning phantom power on or off. Allow the system to adjust for a couple of 
seconds, before setting the input gains. 

 

Only use system indoors, avoid contact with water or other liquids. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always disconnect power from the mains, when system is not used. Only handle the power cord by 
the plug. Never pull out the plug by tugging the power cord. 

 

Always operate the unit with the AC ground wire connected to the electrical system ground. 

 

Make sure you do not use the wrong kind of cables or defective cables. 

 

Make sure that the signals into the mixer are balanced, otherwise hum could be created. 

 

Make sure you use DI boxes to balance unbalanced signals; All incoming signals should be clear. 

 

Make sure that the available voltage is not higher than stated on the rear panel.  

 

Make sure that the power cord is never crimped or damaged. Check the system and the power 
cord from time to time. 

 

Please turn off the power switch, when changing the power cord or signal cable, or select the input 
mode switch. 

 

Extreme frequency boosts in connection with a high input signal level may lead to overdriving your 
equipment. Should this occur, it is necessary to reduce the input signal level by using the INPUT 
control. 

 

To emphasize a frequency range, you do not necessarily have to move its respective control 
upward; try lowering surrounding frequency ranges instead. This way, you avoid causing the next 
piece of equipment in your sound path to overdrive. You also preserve valuable dynamic reserve 
(“headroom”). 

 

Avoid ground loops! Always be sure to connect the power amps and the mixing console to the 
same electrical circuit to ensure the same phase! 

 

If system is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the system has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your system. Leave the 
system switched off until it has reached room temperature. 

 

If your Dap Audio device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Dap Audio dealer for service. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

For replacement use fuses of same type and rating only. 

 

WARRANTY: Till one year after date of purchase. 

 

Operating Determinations 

This system is not designed for permanent operation. Consistent operation breaks will ensure that the 
system will serve you for a long time without defects. 
 
If this system is operated in any other way, than the one described in this manual, the product may suffer 
damages and the

 

warranty becomes void.  

Any other operation may lead to dangers like short-circuit, burns, electric shock, etc. 
 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property ! 

 

 

Summary of Contents for ACX-2

Page 1: ...ACX 2 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D1905 MANUAL ENGLISH...

Page 2: ...ns 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Connection modes 9 Stereo connection example 9 Mono connection exam...

Page 3: ...this manual Before you initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do not use the system To maintain perfect conditio...

Page 4: ...necessary to reduce the input signal level by using the INPUT control To emphasize a frequency range you do not necessarily have to move its respective control upward try lowering surrounding frequenc...

Page 5: ...r UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addre...

Page 6: ...Inputs 2 x XLR inputs 2 x 6 3 mm jack Input impedance 20 KOhm balanced Features S N Rate A weight 95 dB Freq response 3 Hz 40 kHz 0 3 dB THD 0 004 typ 4 dBu 1KHz Crossover freq range 80 Hz 10 kHz Pha...

Page 7: ...switch Mute button Low gain Channel 1 2 This button will mute the Low frequency band If you mute the Low frequency band you will only hear the High frequency band Low gain Channel 1 2 The Low gain ad...

Page 8: ...6 dB x oct up to 22 5 kHz Channel 1 output low jack 6 3 mm Balanced stereo 6 3 mm jack output for the Low frequency band in stereo mode In the mono mode this is a mono 6 3 mm jack output for the Low f...

Page 9: ...ut for the High frequency band Channel 1 output high XLR Balanced stereo XLR output for the High frequency band in stereo mode In the mono mode this is a mono XLR output for the High frequency band IE...

Page 10: ...ote Switch the ACX 2 in the stereo mode as indicated in the figure above Link all the cables before connecting electric power First plug the ACX 2 into a proper electric power supply then the amplifie...

Page 11: ...ch the ACX 2 in the mono mode as indicated in the figure above Link all the cables before connecting electric power First plug the ACX 2 into a proper electric power supply then the amplifiers If you...

Page 12: ...ir life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced...

Page 13: ...rewdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the replacement fuse into the holde...

Page 14: ...3mm jack Output impedance 300 Ohm balanced Features S N Rate A weight 95 dB Freq response 3 Hz 40 kHz 0 3 dB THD 0 004 typ 4 dBu 1KHz Crossover freq range 80 Hz 10 kHz Phase correct range 0 180 Dynam...

Page 15: ...14 ACX 2 Ordercode D1905 Dimensions...

Page 16: ...2016 DAP Audio...

Reviews: