background image

R

www.danvex.fi

Timer Operations 

Timer Switch On

1. Press "Timer On" button to set time for timer-on switching. 
Press the button once to change the time interval of 1 hour in 
a cyclic manner of 6, 7, 8 ...12 ..1, 2..5, 6 (The display is 
showing the previous time as the starting time of the present 
setting). If the button is held down, the time interval will 
increase progressively by 1 hour unit.

2. 

Point the remote controller towards the receiver on the unit, 

Press "Timer Confirm" button to send the timer setting to the 
dehumidifier. Then the timer light on the unit lights up, 
indicating that the unit is in the timer mode. When it reaches 
the switch-on time, the dehumidifier will operate in the pre-set 
modes.

NOTE:

Before timer

 

operation, please set the operation mode, 

temperature, air flow etc. on the remote controller, With timer being 
set to switch-on mode. the Dehumidifier will operate according to 
the last setting.
Usually, timer-on setting is made while the dehumidifier is not 
in operation. If timer-on is set while the dehumidifier is running, 
then the unit will shut down immediately and re-start at the pre-set 
time.
If the "On-Off" button is pressed while the unit is under timer-on 
setting, then the unit will start immediately, the timer setting is cancelled and the timer light will be off.

Timer Switch Off

1. Press "Timer Off" button to set time for timer-off switching. Press the button once to change the time interval 
of 1 hour in a cyclic manner of 6, 7, 8 ...12 ..1, 2..5, 6 (The display is showing the 
previous time as the starting time of the present setting). If the button is held down, the time interval will 
increase progressively by 1 hour unit.

2. 

Press "Timer Confirm" button to send the timer setting to the Dehumidifier. Then the timer light on the unit 

lights up, indicating that the unit is in the timer mode. When it reaches the switch-off time, the air-conditioner 
will automatically shut down.

NOTE:

Timer-Off can only be set when the Dehumidifier is running.
Timer-On and Timer-Off cannot be set at the same time.
Timer display on the remote controller : While time passes, the display shows the remaining time.
If the "On-Off" button is pressed while the unit is under timer-off setting, then the unit will shut down
immediately, the timer setting is cancelled and the timer light will be off.

Timer Cancellation

Press "Timer-Cancel" button to cancel the timer-on or timer-off settings.

15

Summary of Contents for DEH-1200P

Page 1: ...DanVex DEH 1200 DEHUMIDIFIER INSTALLATION AND OPERATING INSTRUCTIONS...

Page 2: ...R www danvex fi 1 RoHS Please read this instruction manual before using the dehumidifier...

Page 3: ...criptions of Parts Installation note Function of the needle valve Panel Control Remote Controller Operation Guide AUTO Operation Mode Air Direction Adjustment Timer Operations Defrost system Water dra...

Page 4: ...all the air conditioner by yourself because improper works may cause electric shock fire water leakage WARNING WARNING Installation in a inadequate place may cause accidents Do not install in the foll...

Page 5: ...to danger of a electric shock Do not insert a rod or other objects into the inlet or outlet vents otherwise it may cause a electric shock or a fire Do not expose yourself to a single directional airf...

Page 6: ...er supply while cleaning the dehumidifier Please take care not to damage the internal fan which is rotating at a high speed Do not use the dehumidifier for other purposes Do not use it for keeping pre...

Page 7: ...nd the air will become dry Model Capacity L hr Heating capacity W Power consumption W Air flow m3 hr Refrigerant g Power supply Current A Compressor type Compressor brand name Water pump Applicable ar...

Page 8: ...ss flow fan Cover Fan motor Heat exchanger bracket Plastic foam air duct Evaporator Water pan Water fender Plastic base Chassis Compressor Four Way Valve Indoor temperature sensor Drain pipe Electrica...

Page 9: ...n outlet Installation note To ensure dehumidifier is steady during running it prepared top dead plate the installation and use as following Function of the needle valve When the heat pump need to meas...

Page 10: ...imer setting Mode is selected in a sequence Automatic Dehumidifying Fan Heating One press of the button to raise the temperature by 1 One press of the button to lower the temperature by 1 Set the swin...

Page 11: ...cel Timer On and Timer Off settings Air Direction Button Set air louver swinging or stationary On Off Button Press once to start dehumidifier running Press again to stop running Timer Off Button SetTi...

Page 12: ...eating Dehumidifying Fan modes Timer Display It displays the time setting for Timer On or Timer Off in the range of 1 12 hours Air Direction Display When Swing is in display the up down louver of the...

Page 13: ...ture Adjustment Button to set temperature 1 degree lower Hold down the Button to increase of decrease the temperature settings progressively NOTE Range of adjustable temperature settings 18 C 31 Start...

Page 14: ...r will be confirm then to set the dehumidify by button and 5 seconds later will be confirm Fan Selection 2 Starting Operation 3 Press On Off button and when the unit receives the signal it gives out t...

Page 15: ...om swinging It is necessary to adjust the louver angle by means of the remote controller Setting of the louver with the hand may affect its normal operation in which event switch off the unit temporar...

Page 16: ...rt at the pre set time If the On Off button is pressed while the unit is under timer on setting then the unit will start immediately the timer setting is cancelled and the timer light will be off Time...

Page 17: ...compressor had run totally 8 minutes 5 The compressor runs 6 After 15 seconds the 4 way valve shifts 7 Five seconds after its stop the compressor and the fan start for restarting in heating mode 8 Th...

Page 18: ...e Dehumidifier Setting of proper room temperature Do not block the air inlet or outlet Use the timer effectively Close doors and windows during operation If the unit is not to be used for a long time...

Page 19: ...age the coating of the unit may cause discoloring or deformation Air Filter cleaning Press the clasp on the top of the grill and pull the grill out and then the filter will be taken out along a gradie...

Page 20: ...nt flowing in the system During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperature changes Should there be a big noise fro...

Page 21: ......