Operation Setting Menu:
1.
Press and hold the
setting button to enter the operation setting menu. Quick press of
the
setting button will act as ‘confirm’ function to confirm on the parameter being set
and will enter the next parameter setting. Press and hold the
setting button to confirm
the current parameter setting and exit. If there is no activity after 15 seconds on the
Operation Setting Menu, it will exit to the Main Screen.
2.
Dehumidification setting value: (0-99%, default value >60%), press or and hold to set
the desire humidity setpoint.
3.
Humidification setting value: (0-99%, default value <50%),
and
Note: The minimum difference between the dehumidification value and the humidification
value is always greater than 5%, if the humidification value set at 60%, then the
dehumidification value is set at 55% and vice versa.
4.
485 address value setting (1-99, the factory default is 1), press the up and down arrows to
set.
5.
The clock setting, press the up and down arrows to set.
6.
Humidity sensor calibration / offset value setting (default is 0), the left side represents the
current value, the right side is set by the up and down arrows to adjust the value.
7.
Temperature sensor calibration / offset value setting (default is 0), the left side represents
the current value, and the right side is set by the up and down arrows to adjust the value.
Summary of Contents for DD Series
Page 8: ...Page 8 of 39 DD F Series...
Page 11: ...Page 11 of 39 3 8 Ducting Connection Diagram example...
Page 33: ...Page 33 of 39 7 2 Wiring Diagram...
Page 34: ...Page 34 of 39...
Page 35: ...Page 35 of 39...
Page 36: ...Page 36 of 39...
Page 37: ...Page 37 of 39...
Page 38: ...Page 38 of 39...
Page 39: ...Page 39 of 39...