Dantherm HRC 3 User Manual Download Page 4

 

General description 

 

Introduction 

This remote control is designed for the particular and considerate house owner, who is 
especially keen to provide a pleasant indoor climate in his house and to its occupants.  
The remote control communicates wireless with the control panel of the ventilation unit 
up to a range of 30 meter through walls and lightweight floors.  
The remote control can be placed on the shelves or it can be hung on the wall in the 
kitchen or in the sitting room. Hereby the occupants of the house can look after the in-
door comfort and easily adjust the mode of operation if necessary.  

 

Functions 

The following functions can be controlled/activated with the remote control: 

 

Manual operation 

 

Week program mode 

 

Away mode 

 

Night mode 

 

Temperature control - heat, (only possible with after heating coil which is an 
optional accessory) 

 

Temperature control – cooling, by means summer mode, or built-in bypass (ac-
cessory) 

 

Adjust filter change intervals 

 

Automatic demand-control based on relative humidity, or VOC sensor (acces-
sory) 

 

On the remote control the user can read off the following: 

 

Fan step 

 

Outdoor temperature, supply air temperature (into the house), exhaust air tem-
perature (from the house) and room air temperature (measured in the remote 
control) 

 

Day of the week and hour 

 

Relative humidity in the exhaust air duct (the humidity of the house)  

 

Pollution level in the house (only possible with an extra VOC or external CO

2

 

sensor which is optional accessory) 

 

Remaining filter time 

 

 acoustic beeper  

 

Summary of Contents for HRC 3

Page 1: ...1 088037 Version 1 1 07 11 2019 HRC 3 User manual Rev 1 1 en...

Page 2: ...ehold for trykfejl og ndringer Dantherm can accept no responsibility for possible errors and changes Irrt mer und nderungen vorbehalten Dantherm n assume aucune responsabilit pour erreurs et modificat...

Page 3: ...of content Table of content 3 General description 4 Installation 5 Display information 6 User menu 7 Operating information without accessories 12 Operation information with accessories 14 Installer m...

Page 4: ...led activated with the remote control Manual operation Week program mode Away mode Night mode Temperature control heat only possible with after heating coil which is an optional accessory Temperature...

Page 5: ...ower to the unit The unit and the remote control now try to connect with each other for the next 60 seconds and when connection is made data from the unit are shown on the display If pairing is not su...

Page 6: ...clock is used to control week program mode and night mode Info line Alarm Information about various functions and programs Battery low Fan step Four oval fields indicating current fan speed Navigation...

Page 7: ...es by pushing UP or DOWN on the navigation button Change fan speed in manual mode UP or RIGHT navigation button Short cuts Brug navigationstasten som beskrevet i skemaet herunder Button Function Press...

Page 8: ...In Week program mode the unit supplies a variable air exchange which is adapted to the selected family profile P1 P2 P3 etc See the list at the back of this manual The week program number is changed...

Page 9: ...erheating for comfort supply air If afterheating is only required to prevent supply of cold air or draught in convenience the T2 supply air temperature can be used as setpoint and regulation temperatu...

Page 10: ...af terheater icon flashes Press UP DOWN to set the afterheater setpoint T3 and confirm by pressing CENTER 7 T5 afterheater setpoint now flashes quickly 120 min and the af terheater icon flashes Press...

Page 11: ...TIC BYPASS COOLING The built in AUTOMATIC BYPASS COOLING mode is used during summer time when the outdoor temperature is higher than 15 C as long as it is lover than inside air temperature This means...

Page 12: ...asured in the remote control 6 Filter The number of black triangles in the filter symbol indicates how much of the filter lifetime has been used When all triangles are filled and the filter symbol fla...

Page 13: ...n the ap pendix For a further description of how to correct any failure in the ventila tion unit please see the installation manual for this This gives information about time setting week program alar...

Page 14: ...aftercoolers are controlled by the same setpoints as the built in BYPASS COOLING function I e cooling and bypass are always in operation at the same time If an aftercooler is connected it is also used...

Page 15: ...ed by the sensor VOC CO2 concentration is as follows Symbol ppm Description 600 Clean air 600 800 Adequate air quality 800 1200 Slightly polluted air 1200 Polluted air Relative humidity in the room Th...

Page 16: ...te the installer menu until the ventilation unit icon on the display is flashing slowly The installer menu will be active for 60 minutes or until the same button is pressed again Installer menu Follow...

Page 17: ...hes 3 Press CENTER previous RH set point flashes 4 Press UP DOWN in order to adjust RH set point 5 Press CENTER to confirm the new set point and close 6 Press RIGHT for 10 sec till the installer menu...

Page 18: ...icon for the ventilation unit is flashing 2 Press the RIGHT button till the preheater icon in the outdoor air duct T1 flashes slowly 3 Press the CENTER button and the preheater icon shows the actual s...

Page 19: ...the installer menu you can see change the setpoints for BYPASS COOLING on the lo cations shown below T1 SET Bypass Tmin Minimum outdoor temperature where BYPASS COOLING can start T3 SET Bypass Tmax Mi...

Page 20: ...s installed 5 Press UP DOWN to change the setpoint for T1 SET bypass Tmin and con firm by pressing CENTER 6 The setpoint for T3 Bypass Tmax will now flash quickly together with the icons for pre after...

Page 21: ...ostat Accessory E 15 Digital input active fx high water Condensate pump Accessory Week programs Code Week program P 1 Family with kids both parents work outside the home during the day P 2 Family with...

Page 22: ...8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 4 3 2 1 P3 Week program Monday Friday Step 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 1...

Page 23: ...4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 4 3 2 1 P7 Week program Monday Friday Step 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 1...

Page 24: ...1 22 22 23 23 24 4 3 2 1 Weekend Step 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 4 3 2 1 P11 Week program Monday Frida...

Page 25: ...25 088037 Version 1 1 07 11 2019...

Page 26: ...26...

Page 27: ...n Phone 0 121 130 40 Fax 0 121 133 70 infose dantherm com www dantherm se Dantherm Air Handling Suzhou Ltd Bldg 9 No 855 Zhu Jiang Rd Suzhou New District Jiangsu 215219 Suzhou China Phone 86 512 6667...

Page 28: ...28 Dantherm Air Handling A S Marienlystvej 65 7800 Skive Denmark www dantherm com service dantherm com 088037 088037...

Reviews: