Operating information - without accessories.,
continued
Info-line
(Under the clock)
Information about alarms, various settings and battery level are shown in the INFO-
LINE.
Symbol
Description
If the ALARM icon is displayed, there is a failure on the unit, and the defect
component is flashed. At the same time an alarm code is shown in the
INFO-LINE (e.g. E2). This code is described in the alarm code list in the ap-
pendix. For a further description of how to correct any failure in the ventila-
tion unit please see the installation manual for this.
This gives information about time setting, week program, alarms etc. Dis-
play
Description:
A1
AUTO program A1 is chosen.
P1, P2…
Week program No.
BYP6, …
Manual bypass-cooling is activated, 6 hours
FP07, FP06…
Fireplace function is activated, 7 minutes
DEF
Defrost-function, prevents icing up of the heat exchanger
E1, E2…
Alarm code
Low battery level in the remote control
Fan speed
The four oval fields indicate the actual fan step. The more oval symbols are black, the
more air is changed in the house.