Product description
Overall description
Introduction
This section gives you a description of the overall unit.
HCV7 overview
HCV7 ventilation unit is designed to supply fresh air to residential home, by exchanging
heat from outgoing air to incoming air, resulting in virtual no energy loss.
The unit is designed for installation in dry surroundings, with temperatures >12°C. e.g.
utility room or similar heated rooms.
The duct connections can be electronically swapped, providing ability to route the con-
nected ductwork, either to the right of to the left, as described on page 22 .
Use of shortages in
this manual
This manual uses shortages for ventilation terminologies
Short
Description
T1
Outside air coming into the unit
T2
Supply air going from unit to indoor
T3
Indoor extract air going into the unit for heat recovery
T4
Exhaust used air from unit to outside
S1
Temperature sensor no 1
S2
Temperature sensor no 2
S3
Temperature sensor no 3
S4
Temperature sensor no 4
A
Indicating operation mode A where the T2 and T3 is on the LEFT hand side of
the top of the unit. See more at page 22
B
Indicating operation mode B where the T2 and T3 is on the RIGHT hand side
of the top of the unit. See more at page 22
G4
Standard air filter,
F7
Fine filter (Accessory)
BP
Bypass damper
IP
Unique address for the ethernet port.
DHCP Automatic settings of an ethernet adresse provided from an external network
component ( if connecting the unit to Ethernet)
PC
Personel computer running MS Windows
USB Universal serial bus connection– located on almost any computer
LAN Local area network
WAN Wide area network(internet)