11
2. Installation of the unit
2.1 Measuring of ducts
Cut out the stencil from the packaging and tape it onto the wall where you want the unit to hang. Use the stencil to
mark off the position of the ducts and the suspension bar.
You may also use the dimensional outlines on page 39 to make the markings.
Having made the duct openings, measure the depth of the ducts. The ducts are now ready for adjustment and
installation.
2.2 Duct kit
The duct kit is suitable for wall thicknesses from 70 to 350 mm
A) Dantherm duct kit
The duct kit includes the parts shown below:
The duct piece with the filter is placed in the lower duct opening where the air from the swimming pool room is
taken into the unit.
C
CDP 35T 434 mm
CDP 45T 743 mm
CDP 65T 1284 mm
NOTE
!
The suggested minimum space between unit and ceiling and
between unit and floor is 225 mm.
See the dimensional outlines page 39.
Filter
Summary of Contents for CDP 35T