Specifications
Model CD 400-18
PowerSupply 220V-240V (50Hz)
Dehumidity Capacity 18 ltr./24 hours (30
℃
/80 % RH)
Power Consumption 340W
Capacity of water tank Approx.4,5 L
Weight 13kg
Dimensions Height 575mm, Length380mm, Width 225mm
Room Temperature 5
℃
-35
℃
The specification may be subject to change
without notice for purpose of improvement.
Trouble- Shooting
Prior to requesting to repair, please check for the following:
Malfunction
Points to be checked
Measures to be taken
Ref.Page
Check if the power plug is
disconnected.
Insert the plug into an electric outlet fully
and securely.
2
Check if the water tank is full of
water.
Empty the water out of the tank.
2
Check if the water tank is not set
properly in position.
Set the tank to the unit properly in
position.
11
No operation
Check if all the flaps are closed.
Open one of the flaps.
13
Check if the filters get dirty.
Clean the filters as specified.
13
Check to see if the air openings are
blocked up.
Remove obstacles from the air openings.
13
Dehumidified
volume is small
Check if the dehumidifier is in air
clean mode.
Change the operation mode to the
dehumidifying mode.
13
Loud sound
while operating
Check to see if the unit is not
installed as specified.
Install the unit on a level and stable floor.
13
Operation stops
during spot
dehumidifying
Check if the room temperature is
higher than the usable operating
temperature.
The dehumidifying operation will be
started automatically when the
temperature lowers.
13
Check if washed clothes are not
exposed to the air from the unit.
Try to expose the washed clothes to the air
flow.
13
Washed clothes
are not dried
Check if the room temperature is too
low.
Washed clothes are hard to be dried under
low temperature conditions.
13
17