pH
7.2-7.8
Total Alkalinity
80-120ppm as CaCO
3
Total Hardness
80-250ppm as CaCO
3
Total dissolved solids
1000ppm
Saline Water Except PPT22
8000ppm
Chlorine - free Cl Range
1.0-2.0ppm Domestic
Chlorine - free Cl Range
3.0-6.0ppm Commercial
Ozone
0.9ppm Max
Bromine
2-5ppm
Baquacil
25-50ppm
Aquamatic Ionic Purifier
Max 2ppm Copper
IMPORTANT
1. Maximum pressure of water in heat pump circuit should not exceed 3.5kg/
cm
2
(50 psi)
FOR POOL APPLICATIONS THE FOLLOWING ALSO APPLY
2. All Pool Purifying Devices and Chemical Injection Systems to be fitted
down stream of heat pump unless installation is as per Filter dosing. This
includes the practice of dosing chemicals direct into Skimmer Basket, which
results in concentrated corrosive liquids passing over metal components.
3. Water quality must be maintained as follows
10
SD331852 ISSUE 7
OWNER INSTALLATION MANUAL 634ACH/ACL/AHC /1222AC/1234BC/BHC /1834BHC /PP22BC