13.0 REMOTE SEQUENCE END MONITOR INSTALLATION INSTRUCTIONS
REMOTE SEQUENCE END MONITOR
REMOVING 4 CORNER SCREWS
OR CONDUIT
INSTALLATION INSTRUCTIONS
REMOVE MONITOR LID BY
MONITOR BOX BASE TO
WALL FIXING HOLES
PASS CABLE THROUGH CORD
GRIP BUSH & TERMINATE
AS SHOWN
REPLACE MONITOR LID & SCREWS
SECURE CABLE WITH CORD
GRIP BUSH SCREWS
TO CONNECT REMOTE CONDITION MONITOR FACILITY USE 3 CORE CABLE OR CABLES IN
DIA 20mm CONDUIT (TYPICALLY BROWN, BLUE AND GREEN/YELLOW 1.0mm ) AND TERMINATE
TO MONITOR BOX AS SHOWN.
1.
2.
3.
4.
3 CORE CABLE
REMOTE CONDITION MONITOR
ALARM
SOUNDER
ON
SOUNDER
OFF
ISOLATE BEFORE REMOVING
FRONT COVER
GREEN/YELLOW
BLUE
BROWN
2
GRIP GLAND GROMMET
IF 3 CORE CABLE USED
REMOVE & FIT DIA 20mm
CONDUIT IF REQUIRED
TO TERMINALS 44(G/Y) 56(B) 57(BR) ON
TERMINAL BLOCK.
55
261001 ISSUE 11