P
AGE
4
46112/113-0299 <90-00032>
Configuration Straps
The configuration straps set the line clock polarity. When you
set the straps in the POS position, data changes at the rising
edge of the clock pulse signals. When you set the straps in the
NEG position, data changes at the falling edge of the clock pulse
signals. Straps are set for POS edge trigger from factory and
should not be changed in the field.
A Power Input Decoupling Network
The power input decoupling network is a capacitor array that
filters and isolates noise from the +5 VDC operating power. The
46113 SynchMaster module power supply supplies operating
power to the 46112 and 46113 SynchMaster modules. If more
than one 46113 SynchMaster module is at a location only one
46113 SynchMaster module supplies power to its associated
46112 SynchMaster module.
F
IG
. 1 - F
UNCTIONAL
S
CHEMATIC
, 46112
PORT A
RXD D LED
RS 422
DRIVERS
AND
RECEIVERS
TXD A LED
RS 232
DRIVERS
AND
RECEIVERS
UP TO
32 ASYNCHRONOUS
PORTS
(MAX EIGHT __ 46113)
PORT D
PORT C
PORT B
46113
DSM DATA PORT
MODULE
DATA
DATA
DATA
PARALLEL DATA
UART
CONFIGURATION
SWITCHES
PARALLEL DATA
UART
CONFIGURATION
SWITCHES
PARALLEL DATA
UART
CONFIGURATION
SWITCHES
PARALLEL DATA
UART
CONFIGURATION
SWITCHES
DATA
+5 VDC
OUTPUT
+5 VDC
REGULATOR
POWER
SUPPLY
TERMINATION
RESISTORS
" " XPORT
" " R/W
TTL BUSS XRST
" " XUART/SW
DATA BUS XD1
DATA BUS XD0
DATA BUS XD3
DATA BUS XD2
DATA BUS XD5
DATA BUS XD4
DATA BUS XD7
DATA BUS XD6
ADDRESS BUSS XA1
ADDRESS BUSS XA0
ADDRESS BUSS XA3
ADDRESS BUSS XA2
ADDRESS BUSS XA5
ADDRESS BUSS XA4
ADDRESS BUSS XA7
ADDRESS BUSS XA6
RX-
RX+
TX-
TX+
MPO
RD
MPI
TD
RX-
RX+
TX-
TX+
MPO
RD
MPI
TD
RX-
RX+
TX-
TX+
MPO
RD
MPI
TD
TX-
TX+
MPO
RD
MPI
TD
GROUND
-21 to -56 VDC
Functional Schematic, 46113 SynchMaster DATA PORT MODULE
PORT D
RXD D LED
RS 422
DRIVERS
AND
RECEIVERS
TXD D LED
RS 232
DRIVERS
AND
RECEIVERS
PORT C
RXD C LED
RS 422
DRIVERS
AND
RECEIVERS
TXD C LED
RS 232
DRIVERS
AND
RECEIVERS
PORT B
RXD B LED
RS 422
DRIVERS
AND
RECEIVERS
TXD B LED
RS 232
DRIVERS
AND
RECEIVERS
35
17
41
45
43
49
53
42
55
48
36
47
51
44
46
54
50
56
52
40
38
39
22
LINE
SIDE
To
SynchMaster
Controller
Module
46112
1
6
7
3
2
9
4
16
19
8
5
15
14
10
11
12
13
26
25
21
24
20
18
23
32
27
33
29
31
34
28
30
PORT A
RX-
RX+
DROP
SIDE
CIRCUIT DESCRIPTION
N
OTE
:
When the unit initially powers
up, the TX REPEAT LED blinks
on and off at a one second inter-
val if you set any 46113 Synch-
Master port switches incorrectly.
If this happens, recheck the
46113 SynchMaster module
switch settings.